Troubleshooting

Fault
Riveting power
too low, some air
escapes from the
outlet .
Appliance does not
work; compressed air
escapes completely
through the outlet .
PDBNP 14 B1
Possible cause
Moving parts
jammed due to dirt .
Pressure supply too
low .
Moving parts are
jammed due to mate-
rial build-up .
Remedy
Check the pressure supply filter for contamination .
Check the pressure supply filter for contamination .
Lubricate the tool as described in the instructions .
If necessary, repeat the steps outlined above .
Lubricate the tool as described in the instructions .