Max. inflow pressure (p in max) ...0.8 MPa
Max. inflow temperature (T in max) ..40 °C
Pumping rate, water (Q)............ 5.5 l/min
Max. pumping rate, water
(Q max) .................................. 7.5 l/min
Sound pressure level
(L
) ..................... 81,7 dB(A); K
pA
Sound power level
(L
measured ...... 94,5 dB(A); K
guaranteed
.......................... 97 dB (A)
Vibration
(a
) .....< 2.5 m/s
h
The values for noise and vibration were
determined according to
EN 60335-2-79:2012.
Do not exceed the maximum permitted
network impedance of 0.450 Ohms at the
electrical connection point.
The user must ensure that the device is
operated only on a power supply network
that fulfils this requirement.
If necessary, the local power supply com-
pany can be asked for the system imped-
ance.
The stated vibration emission value was
measured in accordance with a standard
testing procedure and may be used to com-
pare one power tool to another.
The stated vibration emission value may
also be used for a preliminary exposure
assessment.
Warning: The vibration emission
value may differ during actual use
of the power tool from the stated
value depending on the manner in
which the power tool is used.
Try to keep the exposure to vibra-
tions as low as possible. Examples
of measures to reduce vibration
exposure are the wearing of gloves
when using the tool and limiting the
working hours. For this purpose all
parts of the operating cycle have to
be considered (for example, times
6
CY
= 3 dB
pA
)
WA
= 2,16 dB
WA
; K=0.15 m/s²
2
when the electric tool is switched off
and times when it is switched on but
running without any load).

Notes on Safety

This section is concerned with the basic
safety rules when working with the pres-
sure cleaner.

Explanation of symbols

Attention!
Before beginning work, familiarise
yourself thoroughly with all the op-
erating elements, particularly with
how they function and operate. Ask
a specialist if necessary.
Attention: Remove the plug from the
socket as soon as the power lead is
damaged or cut.
Also disconnect the plug from the
socket when connecting to the
water supply or trying to eliminate
leaks.
The pressure cleaner is not suitable
for direct connection to the drinking
water supply system.
Safety class II (Double insulation)
Electric appliances should not be dis-
posed of in the domestic garbage.
Operate the equipment only in
an upright and never in a re-
clined position.
CAUTION. pressure cleaners
can be dangerous if they are
not operated correctly! The
jet must never be directed

Werbung