Trouble shooting

Problem
Possible cause
Standard Vario noz-
zle (18) is soiled
Severe
pressure
fluctuations
Standard Vario noz-
zle (18) is blocked
ON / OFF switch
(7) is turned off
Pressure
cleaner is
Damaged power
not operat-
supply cable
ing
Mains fault
Pressure
Air trapped in the
cleaner
pressure cleaner
does not
generate
Drop in the water
any pres-
mains pressure
sure
Connections not fit-
ted correctly
Leaks in
the water
system
Water connection
(14) leaks
16
CY
Remedy
Rinse the standard Vario nozzle (18) with water. If
required, clean the nozzle bore hole with a needle
(see chapter entitled cleaning).
Remove the Standard Vario nozzle (18) and ensure
that the water can discharge from the jet gun (16)
unimpeded. In other words, the device is working
perfectly. The turbo dirt blaster (24) and the rotating
wash brush (2) do not normally get blocked.
Check ON / OFF switch (7)
Switch off the equipment and disconnect from the
mains. Check power supply cable for damage. If
necessary have the power supply cable replaced by
a qualified electrician.
Check the electrical system for conformity with the
data on the rating plate.
Switch on the equipment with the jet gun and with
no nozzle until bubble-free water comes out.
Check the water mains.
Switch off the equipment and disconnect from the
mains. Reconnect the equipment to the water pipes
(cf. "Initial Operation/Set-Up")
Switch off the equipment and disconnect from the
mains. Replace the water connection (14) inc. gas-
ket (cf. "Spare Parts")