9.

Technical data

Rated operating voltage
Operating voltage range
Current consumption at U_b=12 V DC:
- Detector groups open
- Detector groups terminatd with 12k1
- LED indicator
4 detector group inputs with clear function
- Voltage
- Monitoring range:
DG1, DG3, DG4
DG2
2 semiconductor outputs
Protection class as per EN 60529
Environmental class as per VdS
Operating temperature range
Storage temperature range
Dimensions:
- Module s.m. (W x H x D)
- PCB (W x H)
Weight 022325.10
Colour
Honeywell Security
Novar GmbH
Johannes-Mauthe-Straße 14
D-72458 Albstadt
www.honeywell.com/security/de
Mounting and Connection Instructions Block Lock Module BUS-2/BUS-1
800-24336
2018-06-07
© 2018 Novar GmbH
12 V DC
9 V to 15 V DC
max. 5.0 mA
£
0.6 mA in addition per detector group
£
1.3 mA in addition per LED
8 V DC, stabilized, short-circuit protected
12k1 ± 20%
12k1 ± 20% / 6k05 ± 20% (Lock function)
18k15 / 12k1 / 6k05 ± 20% (Mid-position)
"open collector", LOW active,
max. 30 V DC, max. 50 mA per output
IP 30
II
-10 °C to +55 °C
-25 °C to +70 °C
163 x 151 x 39 mm
121 x 90 mm
290 g
traffic white (similar to RAL 9016)