Herunterladen Inhalt Inhalt Diese Seite drucken

Dead Bolt Lock; Key Switch Ss90 - Honeywell BUS-2 Montage, Anschluss, Anleitung

Blockschloss-modul
Vorschau ausblenden Andere Handbücher für BUS-2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mounting and Connection Instructions Block Lock Module BUS-2/BUS-1
6.4

Dead bolt lock

BL Module
Shield
Out 1
0 V
Out 2
+U_b
gn
DG1
gr/pk
0 V
gr
ye
vi
DG2
bk
0 V
pk
wh
*Solder a 12k1 resistor parallel to RX2
6.5

Key switch SS90

BL Module
Shield
Out 1
0 V
Out 2
+U_b
DG1
12k1
0 V
DG2
0 V
Buzzer
external
+
Dead bolt lock
Tamper
11k8
RX4
12k1
RX5
disarmed
12k1*
armed
12k1
RX2
Key Switch SS90
4
+
3
11
12
S2
S3
S2 = Tear-off contact
S3 = Cover contact
12k1
7
R7
S10/5
disarmed
8
S4
12k1
armed
12k1
9
R4
S10/2
Colour abbreviations:
gr
gray
pk
pink
rd
red
gn green
ye
yellow
vi
violet
bk
black
wh white
Alternative
(not as per VdS)
ye
vi
DG2
pk
bk
0 V
Buzzer
external
Set DIP switces:
S10/2 = ON
S10/5 = ON
All others = OFF
Function of switch S4:
The switch S4 must set as a sustained
contact/switch (state of delivery).
Solder in the resistors:
R7 = 12k1
R4 = 2x12k1 parallel (6k05)
12k1
RX1
disarmed
12k1
12k1
RX2
wh
ON
1
2
3
4
5
6
7
25
armed
8