Mounting and Connection Instructions Block Lock Module BUS-2/BUS-1
4.2

Selection of BUS system

Operation at BUS-2:
Operation at BUS-1:
4.3
Operating mode of the switching device
Lock Function:
Setting for Block Lock, Dead bolt lock, Key Switch SS90.
Neutral mid-position:
Setting for Outdoor safety operating unit f.m. (012520).
4.4

BUS user address

Permissible address range: 1 to 63.
- Address allocation at BUS-1
The module occupies 3 addresses.
User type: Door arming module
Only the
lowest
address is set at the module. The module occupies
the subsequent 2 addresses automatically. The 4th address can be
used for a random BUS user with only one address (see illustration
at right).
Possible start address is only every 4. address: 1, 5, 9, 13 and so on.
The highest settable address is
address range is exceeded by the automatically assigned addresses.
Ensure that the automatically assigned addresses are not already
occupied by other users.
- Address allocation at BUS-2
The module only occupies the set address only.
- Set BUS user address
The DIP switches S1/1 to S1/6 serve as coding for the BUS-2 and
BUS-1 user address (see illustration above).
In the event of several users,
address.
5.

Installation guidelines

The BUS connecting cable
diagram below.
The corresponding line cross-sections can be found in the installation instructions of the intruder
alarm control panel (see "Lines").
Keep the shield connections as short as possible to avoid the risk of a short circuit.
Control panel
Data
BUS-2
0 V
or
U_b +12 V DC
BUS-1
0 V
Shield
S1/8 ON
S1/8 OFF
S1/7 = OFF
S1/7 = ON
61
, otherwise the permissible
each
user must be assigned its
must
be a shielded, twisted pair line. Wires must correspond with the
Neutral mid-position
Address
own
BUS-2/BUS-1
S1
BUS-2
BUS-1
Lock function
32
16
8
BUS-2
4
BUS-1
2
1
ON
Address allocation at BUS-1
1
2
3
5
6
7
9
10
11
13
14
15
49
50
51
53
54
55
57
58
59
61
62
63
Module
21
Valence
4
8
12
16
52
56
60
X
Data
0 V
+12 V DC
0 V
Shield