3.3

Semiconductor outputs

Two "open collector" outputs, LOW active, short circuit protected, current limited (50 mA).
- Output 1:
Activation of an external buzzer
- Output 2:
Activation of the block lock coil (block release)
3.4

Data transmission

Data transmission BUS-1
The states of the 4 detector groups are transmitted via 3 addresses from the module to the panel.
The function of the control signals are transmitted via the first two addresses from the panel to the
module.
Address
Normal
state
Normal
n
operation
Mid-position
n+1
operat. unit.
(DG2)
BSC Normal
n+2
operation
(DG3)
Data transmission BUS-2
The states of the 4 detector groups and the control signals are transmitted separately in the bus
protocol via
one address
Triggering of a tamper by the
protocol.
4.

Programming

4.1

Overview

The DIP switches are only queried during initialization with a reset (when the operating
voltage is applied). Therefore, set the switch in de-energized state. The setting of this
switch is then only effective
DIP switch position on the PCB
LD1
LD2
LD3
LD4
Mounting and Connection Instructions Block Lock Module BUS-2/BUS-1
1. Message
Tamper
(DG1 + 2)
Armed
(DG2)
BSC triggered
(DG3)
.
cover contact
when energized
S1
2. Message
No Control
signal
OC triggered
Normal
(DG4)
state
Disarmed
OC clear
(DG2)
(DG3)
Normal
– – –
state
is signalled separately to the control panel in the bus
!
Neutral mid-position
1. Control
signal
Buzzer on
(Output 1)
Block release
(Output 2)
– – –
(no
evaluation)
S1
BUS-2
BUS-1
Lock function
Address
BUS-2
BUS-1
2. Control
signal
– – –
(no
evaluation)
– – –
– – –
(no
evaluation)