The following options are available:
♦
Attach a maintenance unit with an oiler to the compressor .
♦
Install a fitted oiler into the compressed-air line or the compressor .
♦
Add 3–5 drops of pneumatic oil into the connector nipple
every 15 minutes of operation .
Connecting to a compressed-air source
NOTE
►
Before connecting the compressed-air source
–
the correct working pressure (3–6 .3 bar) must be fully
reached, and
–
you must ensure that the trigger is in its initial position .
♦
Attach the tool to a compressor by connecting the connector
nipple
with the supply hose of the compressed-air source .
♦
The compressed-air source must be equipped with a pressure
reducer so that you can regulate the air pressure .
PDKS 6.3 B3
GB │ MT
│
69
■