Herunterladen Inhalt Inhalt Diese Seite drucken

Proper Use; Technical Data - Parkside PKO 400 B2 Bedienungs- Und Sicherheitshinweise Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für PKO 400 B2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 74

4. Proper use

The compressor is designed to generate com-
pressed air for compressed-air driven tools which
can be driven with an air volume of up to approx.
360 l/min (e.g. a tire infl ator, blow-out pistol and
paint spray gun). Compressed air tools with very
high air consumption have only limited suitability
for use with this compressor. For tools with high air
consumption (e.g. orbital sanders/grinders, rod
grinders, hammer screwdrivers), check whether
the compressor's air output is suffi cient to operate
the tool in question. The volume of air supplied by
the compressor must be greater than the volume
of air consumed by the compressed air tool at its
operating pressure.
The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the manufac-
turer will be liable for any damage or injuries of
any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
Anl_4010164.indb 11
Anl_4010164.indb 11
GB

5. Technical data

Mains connection: .........................230 V ~ 50 Hz
Motor rating kW: ................................ S1 2400 W
.................................................. S2 30 min 2600 W
-1
Compressor speed min
Operating pressure bar: .............................. max. 8
Pressure vessel capacity (in liters): .....................50
Theoretical suction rate l/min.: .........approx. 360
Effective delivery rate at 7 bar: approx. 170 l/min
Sound power level L
WA
K
uncertainty: ...............................................2 dB
WA
Sound pressure level L
pA
K
uncertainty: ................................................2 dB
pA
Protection type: ................................................IP20
Weight of the unit in kg: ....................approx. 38.5
Oil (15W 40) ...................................................0.7 l
Load factor:
A load factor of S2 30 min (intermittent periodic
duty) means that you may operate the motor
continuously at its nominal power level (2600
W) for no longer than the time stipulated on the
specifi cations label (30 min). If you fail to observe
this time limit the motor will overheat. During the
OFF period the motor will cool again to its starting
temperature.
The noise emission values were measured in ac-
cordance with EN ISO 2151: 2008.
- 1 1 -
: .............................. 2850
in dB: ............................96
in dB: .......................... 74
25.03.13 15:56