WATER DRAINAGE METHOD

When there is excess water condensation inside the unit, the appliance stops running
and shows
water condensation needs to be drained using the following procedures:
MANUAL DRAINING (FIG.24)
1. Unplug the unit from power source.
2. Place a pan(not supply) under the lower drain plug. See diagram.
3. Remove the lower drain plug.
4. Water will drain out and collect in the pan.
5. After the water is drained, replace the lower drain plug firmly.
6. Turn on the unit.
CONTINUOUS DRAINING (fig.25)
1. Unplug the unit from the power source.
2. Remove the drain plug. While doing this operation some residual water may spill so
please have a pan (not supply) to collect the water.
3. Connect the drain hose (1/2" or 12.7mm, maybe not supplied ). See diagram.
4. The water can be continuously drained through the hose into a floor drain or bucket.
5. Turn on the unit.
Drain outlet
Drain cap
NOTE
Please be sure that the height of and section of the drain hose should not be higher than
that of the drain outlet, or the water tank may not be drained, (fig.26 and fig.27)
(FULL TANK as mentioned in SELF-DIAGNOSE). This indicates that the
www.blaupunkt.com
Drain
outlet
Drain cap
Drain hose
29