Note:
Minimum height of installation
than the lowest point of the collecting
tank or vessel.
Note:
ontinuous slope
The feed line must always be laid with a
continuous downward slope. If the space
for installation is too restricted, the lower
feed line must be provided with a sepa-
rate venting line.
Note:
Venting line
In the case of large condensate quanti-
ties, it will always be necessary to install
a separate venting line.
Note:
Continuous slope
It is important to avoid water pockets when
using a pressure hose as a feed line!
Note:
Continuous slope!
Water pockets must also be avoided
when laying a feed pipe.
BEKOMAT 13 | 13 CO | 13 CO PN25 | 13 CO PN40
français
Important :
hauteur minimale de montage
dessous du point le plus bas du collecteur
(par exemple, la cuve)
Important:
pente continue
Important:
En cas de forte production de condensat,
Important :
pente continue !
Important :
pente continue !
nederlands
Belangrijk:
Minimale inbouwhoogte!
De toevoerhoogte dient altijd onder het
aftappunt van de verzamelruimte te liggen
(b.v. ketel).
Belangrijk:
Continue verval!
Het kondensaat moet altijd met verval
(min. 1%) toestromen. Ingeval van een
beperkte inbouwhoogte dient een aparte
ontluchtingsleiding te worden geïnstal-
leerd.
Belangrijk:
Ontluchtingsleiding
Bij grote kondensaathoeveelheden dient
-
altijd een aparte ontluchtings-leiding te
worden geïnstalleerd.
Belangrijk:
Op afschot monteren!
Wanneer een slang als toevoerleiding
gebruikt wordt, mag er in geen geval een
waterslot ontstaan!
Belangrijk:
Continue verval!
Ook bij het aanleggen van de afvoerlei-
ding een waterslot vermijden.