Herunterladen Inhalt Inhalt Diese Seite drucken

Application; Appliance Layout - AEG ETH 13 Bedienung Und Installation

Elektro-heizkessel
Vorschau ausblenden Andere Handbücher für ETH 13:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Contents / Installation - for contractors
Contents
1.
Application ............................................................................................................................................................................. 16
2.
Appliance layout .................................................................................................................................................................... 16
3.
Installation .............................................................................................................................................................................. 17
4.
Commissioning ...................................................................................................................................................................... 17
5.
Mode of operation ................................................................................................................................................................. 18
6.
safety equipment................................................................................................................................................................... 18
6.1
High limit safety cut-out of the heating elements .................................................................................................................... 18
6.2
Return temperature limiter ....................................................................................................................................................... 18
6.3
Monitoring the system pressure .............................................................................................................................................. 18
6.4
Monitoring the circulation pump .............................................................................................................................................. 19
6.5
Frost protection ........................................................................................................................................................................ 19
6.6
Priority control .......................................................................................................................................................................... 19
6.7
Circulation pump protection ..................................................................................................................................................... 19
7.
Block diagram ........................................................................................................................................................................ 19
8.
Specification .......................................................................................................................................................................... 19
9.
safety instructions ................................................................................................................................................................ 21
10.
Warranty, environment and recycling ................................................................................................................................. 21
note
Installation (water and power connections), commissioning, maintenance and repairs on the appliance may only be carried
out by the trained installation engineer or customer support installer, taking into account the information in these operating
and installation instructions.

1. Application

The electric boiler ETH electronic is designed for sealed unvented and open vented water heating systems. It is suitable as a
standard heat source or as central heating backup for stoves or solar thermal systems. The ETH can be used in conjunction
with conventional radiators, an underfloor heating system or a ventilation system.
The series enables optimum matching of the output to the building's heat demand.
Standard appliance outputs: 13 kW, 15 kW, 18 kW, 21 kW, 24 kW.
The ETH's integral microprocessor control unit, as well as the use of triacs, guarantees convenient, quiet operation, and the
appliance parameters are matched in real time to the relevant conditions, thus lowering energy consumption.

2. Appliance layout

10
3
2
1
9
16
1
Copper cylinder with heating cartridge
4
2
Automatic air vent valve
3
Terminal strip
4
Contactor
5
5
Microprocessor control unit
6
Pressure switch
7
Circulation pump
8
Pump air vent valve
7
9
Connectors
10
Cable entry
6
8

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Eth 15Eth 18Eth 21Eth 24

Inhaltsverzeichnis