Filling the oil mister unit
CAUTION!
►
Before filling or removing the oil reservoir
make sure that the compressed air mainte-
nance unit has been disconnected from the
compressed air source.
♦
Remove the oil reservoir
locking ring
clockwise (see fig. E). Fill the oil
reservoir
with suitable compressor oil until
the max. marking is reached (see Fig. B).
♦
Then manually rotate the oil reservoir anticlock-
wise to the desired position
(fig. E)
PDWE 8 B2
by turning the
(do not use tools).
Use
CAUTION!
►
Ensure that the connected compressed air line
is clean and oil-free so that the compressed
air maintenance unit can be used properly.
Also make sure that the compressed air
system is pressure-free. In order to minimise
pressure losses, it is preferable to keep the
compressed air lines as short as possible.
♦
Connect the compressed air maintenance unit
to the compressed air source.
♦
First release the locking device by pulling the
air pressure regulator
♦
Set the air pressure regulator
setting by rotating it anticlockwise. The desired
settings are adopted by pressing the air
pressure regulator
♦
Connect the compressed air supply line of the
tool to be connected to the quick coupling
(on the right side – output) of the compressed
air maintenance unit. A triangle "▸" on the
surface of the unit indicates the flow direction
of the compressed air.
♦
Connect the compressed air supply line of
the compressed air source via the connector
nipple
(on the left side inlet) of the compressed
air maintenance unit. A triangle "▸" is marked
on the surface in close proximity to the inlet,
which indicates the flow direction of the
compressed air.
(fig. F)
upwards (see Fig. F).
to the lowest
downwards.
GB │ CY
│
5
■