Herunterladen Inhalt Inhalt Diese Seite drucken

Status Indication - Honeywell IDENT-KEY 3 Montage, Anschluss, Anleitung

Bus-2
Vorschau ausblenden Andere Handbücher für IDENT-KEY 3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mounting and Connection Instructions IK3 Evaluation Unit BUS-2
For all other connections
see Chapter 9
9.7.3

Status indication

Two operating states of the single access entry portal are indicated, either p
or turnstile:
Personal interlock
Operating state 1
Other door open
Operating state 2
Manway occupied
Note:
The status indication is not compulsory with the turnstile
1k
1k
red
yellow
EMERGENCY OPEN button
Data
Release
0 V
DB1
NCC
ST23
ST11
Shield
Turnstile
release
Turnstile
Release turnstile
Turnstile/empty space occupied
Suggestion for indication with 2 LEDs:
Red:
Other door open / release turnstile
Yellow:
Manway occupied /turnstile/empty space occupied
Activation by other consumers:
Both of the outputs supply up to max. 50 mA at 12 V DC.
A free wheeling diode is required for inductive consumers (e.g. relay).
EU
Presence-/empty space monitoring
NC (normally closed contacts)
Rel 2
M
NOC
ST12
ST13
Status indications
U_ext
+
0V
ST14
ersonal interlock