60
9.7
AC application as single entry access portal
In addition to the possibilities described in Chapter 2, a single entry access portal can be realized
with the IK3 system that complies with the VdS guidelines of Class C for access control systems. The
system can be designed as a personal interlock or be equipped with a turnstile.
Applicable readers: see schedule in Chapter 4
Prerequisites: Cent. control unit software
WINFEM 100.10
Function in conjunction with MB-Secure in preparation
In case of alarm, the readers can be operated at all times irrespective of the operating
state of the single entry access portal.
The time for "Presence and dwell time monitoring" has to be programmed as "Detector
group delay".
9.7.1
Personal interlock
Exterior reader 2
Status display 2
Interior reader 2
(or AC button)
Interior reader 1
(or AC button)
Status display 1
Exterior reader 1
BUS-2
Control
panel
Opening contact
Bolt switching contact
Door strike
*)
Blocking element
Status indication
Exterior reader 1 Interior reader 1
*) Door strike with armature contact
and monitoring contact
The exterior reader 1 can also be used for arming/disarming.
Mounting and Connection Instructions IK3 Evaluation Unit BUS-2
from V05.xx (MB100, HB24/48 with Index .10)
from V05.xx
Indoors
(e.g. strong room, Class C)
Internal door
External door
Outdoors
(e.g. Class A)
External door
EU 1
Data
Release
IK3 evaluation
unit
023312.17
Presence control
(from V03.02)
F
I
F
I
1
2
3
1
2
3
4
5
6
4
5
6
7
8
9
7
8
9
r
3
r
3
0
0
0 V
(or AC button)
EU 2
Presence and dwell time
monitoring
e.g. security mats, light
barriers etc.
EU 1
BUS-2
Release
e.g. security mat
Opening contact
normally
closed
Door strike
*)
contact
Status indication
Internal door
EU 2
Data
IK3 evaluation
unit
023312.17
(from V03.02)
F
I
F
I
1
2
3
1
2
3
4
5
6
4
5
6
7
8
9
7
8
9
r
3
r
3
0
0
Exterior
Interior
reader 2
reader 2
(or AC button)