Electronic Fittings/Cylinders as switching devices

2.4.1

Functions

1.
Access control functionality
Data carrier with access control rights required
2.
Intrusion panel set/unset
Data carrier with set/unset rights required
For details please see Mounting and Operating Manual Trafficpoint RS-485 (P32815-45-002-xx).
2.4.2

System design

Operation of radio components (electronic door fittings/cylinders, typ XS Pro) as switching devices
in combination with intrusion panels. For bidirectional remote control, Trafficpoint RS-485 is
working as interface between XS Pro components and IK3 EU BUS-2.
At one Trafficpoint
up to 8 XS Pro components
XS Pro fitting
XS Pro cylinder
up to 10 m
max. 8 per module
Conditions:
- ICP: from V12.xx
- IK3 EU BUS-2: from V11.xx
- WINFEM Advanced: from V12.xx
Occupied switching devices:
Each IK3 EU occupies
Trafficpoint itself is not rated as a switching device).
2.4.3

System extension

Depending on the required number of doors within your system/projekt, the system could be
expanded by using additional IK3 EUs (alternatively Control Door Module for MB is usable).
Maximum number of possible doors, depends on number of switching devices which will be
supported by the used intrusion panel.
Mounting and Connection Instructions IK3 Evaluation Unit BUS-2
Trafficpoint RS-485
(max. 8 per IK3 EU)
one
switching devices plus the number of operated XS Pro components (The
(randomly mixed) can be operated simultaneously.
BUS-2
IK3 EU
RS-485
BUS-2
Betrieb
SAlarm SStörung
System-
Störung
Bereiche
Meldungen
B
wählen/
A
Einbruch
7
Ü
8
9
ansehen
ansehen
B
S
O
Sabotage
E
R
N
Gruppen
F
D
ansehen/
Zusatz-
Überfall
4
A
5
E
6
G
F
funktionen
L
R
sperren
L
F
Pol.-Notruf
F
U
U
N
K
Melder
Eingabe
Info 1
1
N
2
3
M
ansehen/
E
Quittierung
K
T
sperren
Bedienende
T
I
Info 2
I
O
O
N
nein
ja
N
ALARMSTOP
Intern
Info 3
unscharf
scharf-
0
AUS
EIN
löschen
schalten
Info 4
Alarmzentrale
561-MB100
Z
A509
024X
VdS
- Zulassungs-Nr.
Control panel
MB24 / MB48 / MB100.10
MB-Secure in prep.
Total numbers of doors: 9 per IK3 EU BUS-2
(1x Door strike + 8x XS Pro via radio)
Enhanced system
(see below)
up to 4 readers
(types see Chapter 4.)
F
I
RS-485
1
2
3
4
5
6
7
8
9
r
0
3
WINFEM
Advanced
PC with
WINFEM Advanced
Door
strike

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis