Herunterladen Inhalt Inhalt Diese Seite drucken

Honeywell IDENT-KEY 3 Montage, Anschluss, Anleitung Seite 25

Vorschau ausblenden Andere Handbücher für IDENT-KEY 3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mounting and Connection Instructions IK3 Operating Unit with Keypad
Activate adjustment mode:
The adjustment mode is activated via programming
or in "Stand alone programming mode".
The activated adjustment mode is indicated at the
operating unit by the bottom green LED that flashes
briefly twice followed by a long pause.
LED indicators during the setting process:
The flashing rhythm of the green LED indicates
whether transmission is safe at many (a), a few (b)
or only at one (c) of the 16 possible power stages.
This is an indication of how much power is still
available up to the maximum possible distance.
If the transponder reaches the
range
, the green LED only flashes once (c). The
yellow LED
flashes additionally and signalizes that
a greater distance cannot be exceeded.
Important:
During adjustment, hold the transponder
steadily in the reading range. We recommend using a non-metallic object as a "spacer"
between the operating unit and the transponder.
As the writing cycle requires more power than the reading cycle, the actual transmission
distance for the write/read transponders is approx. 1.5 to 2 cm shorter than the tran-
sponder that is being adjusted.
Adjust
-
Hold an IK2 / IK3 transponder at the desired distance to the oper-
ating unit.
-
As soon as the transponder is identified,
begins to flash.
-
Adjustment begins LED indicator see above)
-
After approx. 5 sec. adjustment is completed.
Acknowledgement:
- Brief
acoustic signal
- The
adjustment indicator goes off
- The adjusted distance ist stores and indicated.
-
Remove transponder.
After a dead time of approx. 3 sec. the adjustment mode indicator flashes again.
"
"
Repeat adjustment
Adjustment can be repeated at any time.
Condition: The adjustment mode must be activated, the adjustment mode display must flash.
Adjust as described above.
Deactivate adjustment mode
The adjustment mode is deactivated via the programming or in the "stand alone" programming
mode (see Chapter 7.) depending on the type of activation.
maximum possible
(
.
F
a)
b)
c)
F
top green LED
Activate
adjustment mode
I
Transponder identification
Maximum range
Adjustment mode
I
or other
transponder
25

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis