5
Alarm button
(not all models)
The alarm signal sounds simultane
ously with illumination of the red
alarmindicator. The alarm stops when
the red indicator light extinguishes
or the alarmbutton is pressed.
Note ambient
temperature and
ventilation
The climatic class can be found on the
rating plate. It specifies the ambient
temperatures at which the appliance may
be operated. The rating plate can be
found inside the appliance at the bottom
left hand side.
Climatic category
SN
N
ST
T
Ventilation
The air at the back of the appliance will
heat up. This warm air must be allowed to
freely escape, otherwise the refrigerating
machine must perform more. This raises
electricity consumption. Hence, the
air inlet and outlet apertures should never
be covered or blocked off!
Permitted ambient
temperature
+10 °C to 32 °C
+16 °C to 32 °C
+16 °C to 38 °C
+16 °C to 43 °C

Installing the appliance

Install the appliance in a dry, well
ventilated room. The installation location
should neither be exposed to direct
sunlight nor near a heat source, e.g.
a cooker, radiator, etc. If installation next
to a heat source is unavoidable, use
a suitable insulating plate or observe the
following minimum distances to a heat
source:
3 cm to an electric cooker.
30 cm to an oil or solid fuel cooker.
Connecting the
appliance
After installing the appliance, wait at least
½ hour until the appliance starts up.
During transportation the oil in the
compressor may have flowed into the
refrigeration system.
Before switching on the appliance for the
first time, clean the interior (see Cleaning).
The socket should be freely accessible.
Connect the appliance to 220 240 V/
50 Hz alternating current via a correctly
installed earthed socket. The socket must
be fused with a 10 A to 16 A fuse.
If the appliance is to be operated in
a non European country, check on
the rating plate whether the indicated
voltage and current type correspond to
the values of your mains supply. The
rating plate is situated in the bottom
left hand side of the appliance. The power
cord may be replaced by an electrician
only.