Herunterladen Diese Seite drucken
Vorschau ausblenden Andere Handbücher für Talis E2:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Attention! The fitting must be installed, flushed and
tested after the valid norms.

Operation

The mixer is actuated by lifting the lever head.
Swivel to the left = hot water, swivel to the right =
cold water.
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow 0,3 MPa:
(1 MPa = 10 bar = 147 PSI)
Test certificate
32675XXX/33655000:
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 14.
No adjustment is necessary when using a continuous
flow water heater.
Fault
Mixer stiff
Mixer dripping
Hot water temperature too low
No cold water
Instantaneous water heater starts
up when cold water is selected
English
max. 1 MPa
1,6 MPa
max. 80° C
65° C
approx. 32 l/min
WRAS
Cause
- Cartridge defective, calcified
- Cartridge defective
Sedimentation
- Hot water limiter incorrectly set
- Crossflow
Spare parts (see page 3)
1
handle Talis E²
1.1 screw cover
2
handle Focus E
3
handle Fcus S
4
handle Talis S
5
handle Talis E
5.1 screw cover
6
escutcheon
7
flange Talis E²
8
fixing screw
9
sub plate
10
nut
11
locking screw
12
seal
13
noise reduction
14
cartridge cpl.
15
extension set 25 mm
16
extension set 22 mm
17
flange
Remedy
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Exchange seal (12),
31692000
96338000
31791000
31793000
32092000
33091000
94191000
96452000
96348000
96454000
96447000
95007000
96059000
95008000
94073000
92730000
13595000
13596000
95010000
o-ring seal (12.1)


Werbung

loading