8) ELECTRICAL CONNECTION

IMPORTANT: the appliance must be
installed following the manufacturer's
instructions. The manufacturer will not be
liable for injury to persons or animals or
property damage caused by an incorrect
installation.
The electrical connections of the appliance
must be carried out in compliance with the
provisions and standards in force.
Before connecting the appliance, check that:
- the voltage matches the value shown on the
specification plate and the section of the wires of
the electrical system can support the load, which
is also indicated on the specification plate.
- The electrical capacity of the mains supply and
current sockets suit the maximum power rating of
the appliance (consult the data label applied to the
underside of the hot plate);
- The socket or system has an efficient earth
connection in compliance with the provisions and
standards in force. The manufacturer declines all
responsibility for failing to comply with these
provisions.
When the appliance is connected to the
electricity main by a socket:
- Fit a standard plug suited to the load indicated on
the data label to the cable.
- Fit the wires following figure n. 11, taking care of
respecting the following correspondences:
Letter L (live) = brown wire;
Letter N (neutral) = blue wire;
Earth symbol
= green - yellow wire.
- The power supply cable must be positioned so
that no part of it is able to reach an temperature
of 90 °C.
- Never use reductions, adapters of shunts for
connection since these could create false contacts
and lead to dangerous overheating.
- The outlet must be accessible after the built-in.
When the appliance is connected straight to the
electricity main:
- Install an omnipolar circuit-breaker between the
appliance and the electricity main. This circuit-
breaker should be sized according to the load
rating of the appliance and possess a minimum 3
mm gap between its contacts.
- Remember that the earth wire must not be
interrupted by the circuit-breaker.
INSTALLATION
- The electrical connection may also be protected
by a high sensitivity differential circuit- breaker.
You are strongly advised to fix the relative yellow-
green earth wire to an efficient earthing system.
Before performing any service on the electrical part
of the appliance, it must absolutely be disconnected
from the electrical network.
WARNINGS:
all our appliances are designed and
manufactured in compliance with European
standards EN 60 335-1, EN 60 335-2-6 and
EN 60 335-2-102 plus the relative amendments.
The appliance complies with the provisions of
the following CEE Directives:
- CEE 2004/108/CE regarding to electromagnetic
compatibility.
- CEE 2006/95/CE regarding electrical safety.
- CEE 2011/65 / UE on the restriction of use of
certain hazardous substances.
- Regulation (EU) No 65/2014 supplementing
Directive 2010/30 / EU.
- Regulation (EU) No. 66/2014 supplementing
Directive 2009/125 / EC.
Standards EN 30-2-1, EN 60350-1, EN 60350-2,
EN 50304.
If the installation requires modifications to
the home's electrical system or if the
socket is incompatible with the appliance's
plug, have changes or replacements
performed by professionally-qualified
person. In particular, this person must also
make sure that the section of the wires of
the socket is suitable for the power
absorbed by the appliance.
66