Operation
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted
operation in the first 3 minutes. This is to protect the unit.
Operation will automatically start after 3 minutes.
POWER MANAGEMENT feature(on some models)
When the ambient temperature is lower than the setting
temperature for a period of time, the unit will be
automatically operate power management feature. The
compressor and fan motor stop. When the ambient
temperature is higher than the setting temperature, the unit
will be automatically quit the power management feature.
The compressor and (or) fan motor run.
NOTE: For unit with power management light, the light
will illuminate under this feature.
Water drainage
-During dehumidifying modes, remove the upper drain
plug from the back of the unit, install the drain connector
(5/8" universal female mender) with 3/4" hose(locally
purchased). For the models without drain connector, just
attach the drain hose to the hole. Place the open end of
the hose directly over the drain area in your basement
floor.
Remove the
upper drain plug
Continuous
drain hose
MODEL A
SCALE 0.500
-During heating pump mode, remove the lower drain plug
from the back of the unit, install the drain connector(5/8"
universal female mender) with 3/4" hose(locally
purchased). For the models without drain connector, just
attach the drain hose to the hole. Place the open end of
the Hose adaptor directly over the drain area in your
basement floor.
NOTE: Make sure the hose is secure so there are no
leaks.Direct the hose toward the drain, making sure that
there are no kinks that will stop the warter flowing.Place
the end of the hose into the drain and make sure the end
of the hose is down to let the water flow smoothly.(See
Figs with
. Do never let it up.(See Figs with
the continuous drain hose is not used, ensure that the
corresponding drain plug and knob are installed firmly to
prevent leakage.
Remove the
lower drain plug
Continuous
drain hose
drain hose
adaptor
SCALE 0.500
MODEL A
Remove the
upper drain plug
Continuous
drain hose
MODEL B
). When
X
Remove the
lower drain plug
Continuous
drain hose
drain hose
adaptor
MODEL B
drain hose
adaptor
-When the water level of the bottom tray reaches a
predetermined level, the unit beeps 8 times, the digital
display area shows "P1" . At this time the air
conditioning/dehumidification process will
immediately stop. However, the fan motor
will continue to operate(this is normal).
Carefully move the unit to a drain location,
remove the bottom drain plug and let the
water drain away. Reinstall the bottom
drain plug and restart the machine until
the "P1" symbol disappears. If the error repeats, call for
service. NOTE: Be sure to reinstall the bottom drain plug
firmly to prevent leakage before using the unit.

Maintenance

WARNING:
-Always unplug the unit before cleaning or servicing.
-DO NOT use flammable liquids or chemicals to clean the unit.
-DO NOT wash the unit under running water. Doing so
causes electrical danger.
-DO NOT operate the machine if the power supply was damaged
during cleaning. A damaged power cord must be replaced with a
new cord from the manufacturer.
Clean the Air Filter
Upper filter
(take out)
Remove the
screw,then
take the lower
filter out.
SCALE 0.500
MODEL A
CAUTION
DO NOT operate the unit without filter because dirt
and lint will clog it and reduce performance.
15
drain hose
X
adaptor
Press the power
cord buckle into
the rear cover.
SCALE 0.500
Uper air filter
(take out)
Lower air filter
(take out)
Remove the air filter
SCALE 0.500
SCALE 0.500
MODEL B