Safety instructions:
Installation
Endress+Hauser
• Install the device according to the manufacturer's instructions and any other valid standards and regulations.
• The intrinsically safe input power circuit of the device is isolated from ground potential and has a dielectric
strength of at least 290 Vrms with respect to it.
• The relationship between the permitted ambient temperature for the electronics housing, dependent on the
range of application and the temperature classes is shown in the tables (Tab. 1 and Tab. 3).
• After aligning (rotating) the housing, retighten the fixing screw (Allen screw on the threaded neck).
• Continuous duty temperature of the cable ≥ Ta +5 K.
• If antenna extensions over 3 m-long are used, they should be fixed mechanically (using guy ropes).
• FMR240 or FMR230 with shut-off mechanism:
the entire arrangement must at least meet the requirements as per IP67 in accordance with IEC/EN 60529.
If the device needs to be disassembled for e.g. service purposes, we recommend securing the
shut-off mechanism against opening or closing it with an additional blind flange.
The operator is entirely responsible for ensuring that the complete arrangement is permissible for the
respective application.
• In case of additional or alternative special varnishing of the enclosure or other metallic parts the danger of
an electrostatic charging must be observed. Do not rub surfaces with dry cloth.
Zone 1 - Application
Tab. 1
Temperature
Maximum
class
permitted
with/without
medium
VU331 display
temperature
Antenna
in Zone 1
T6
+80 °C
+60 °C
T5
+95 °C
+75 °C
T4
+130 °C
+80 °C
T3
+150 °C
1
(functional)*
+80 °C
T3
+195 °C
+80 °C
T2
+250 °C
1
(functional)*
+80 °C
T2
+280 °C
1
(functional)*
+80 °C
T2
+290 °C
+80 °C
T1
+350 °C
1
(functional)*
+80 °C
T1
+400 °C
1
(functional)*
+80 °C
Note: permitted antenna temperature range must be observed
1
*
functional = limited by maximum permitted antenna temperature
• The type of protection changes as follows when the devices are connected to certified intrinsically safe
circuits of Category Ex ib for Equipment Groups IIC and IIB: Ex ib IIC T6 or Ex ib IIB T6.
Do not operate the antenna in Zone 0 if the transmitter is connected to an intrinsically safe circuit of Category
Ex ib.
• The pertinent guidelines must be observed when intrinsically safe circuits are connected together acc.
IEC/EN 60079-14 (Proof of Intrinsic Safety).
(E.g. when using Commubox or handheld terminal DXR375 or other certified apparatus).
Maximum permitted ambient temperature (at the electronics housing /
electronics housing in Zone 1) dependent on the medium temperature
FMR230-
FMR230-
FMR230-
..E or V
..L......
..M......
or K
or D......
+55 °C
+60 °C
+60 °C
+60 °C
+60 °C
+60 °C
+70 °C
+70 °C
+70 °C
+75 °C
+75 °C
+75 °C
+75 °C
+75 °C
+75 °C
+80 °C
+80 °C
+80 °C
+70 °C
+75 °C
+75 °C
+80 °C
+80 °C
+80 °C
+65 °C
+75 °C
+75 °C
+80 °C
+80 °C
+80 °C
+60 °C
+70 °C
+75 °C
+80 °C
+80 °C
+80 °C
not
+70 °C
+75 °C
permitted
+80 °C
+80 °C
not
not
+75 °C
permitted
permitted
+80 °C
not
not
+70 °C
permitted
permitted
+80 °C
not
not
+70 °C
permitted
permitted
+80 °C
PTB 00 ATEX 2118 / XA207F-D
FMR230-
FMR231-
FMR240-
..F or
..........
...........
G......
+55 °C
+50 °C
+55 °C
+60 °C
+60 °C
+60 °C
+70 °C
+65 °C
+70 °C
+75 °C
+75 °C
+75 °C
+65 °C
+65 °C
+70 °C
+80 °C
+80 °C
+80 °C
+70 °C
+65 °C
+70 °C
+80 °C
+80 °C
+80 °C
+70 °C
not
not
+80 °C
permitted
permitted
+65 °C
not
not
+80 °C
permitted
permitted
+65 °C
not
not
+80 °C
permitted
permitted
+65 °C
not
not
+80 °C
permitted
permitted
+55 °C
not
not
+80 °C
permitted
permitted
+55 °C
not
not
+80 °C
permitted
permitted
FMR240-
Wave
guide
antenna
+60 °C
+60 °C
+70 °C
+75 °C
+75 °C
+80 °C
+75 °C
+80 °C
+75 °C
+80 °C
not
permitted
not
permitted
not
permitted
not
permitted
not
permitted
11