Herunterladen Inhalt Inhalt Diese Seite drucken

Jet Pump Unit; Impeller Inspection - Yamaha Waverunner XLT1200 Wartungshandbuch

Vorschau ausblenden Andere Handbücher für Waverunner XLT1200:
Inhaltsverzeichnis

Werbung

INSP
ADJ
2
3
ELECTRICAL/JET PUMP UNIT
1
5. Install:
Battery breather hose 1
Battery
Battery positive lead 2
Battery negative lead 3
Bands
CAUTION:
Connect the positive lead to the battery
terminal first.
Make sure the battery leads are con-
nected properly. Reversing the leads can
seriously damage the electrical system.
Make sure that the battery breather hose is
properly connected and is not obstructed.
Coat the terminals with a water resistant
grease to minimize terminal corrosion.

JET PUMP UNIT

Impeller inspection

1. Check:
Impeller 1
Damage/wear → Replace.
Nicks/scratches → File or grind.
2. Measure:
Impeller-to-housing clearance a
Out of specification → Replace.
Max. impeller-to-housing
clearance:
0.6 mm (0.02 in)
Measurement steps:
Remove the battery leads.
Remove the intake grate and intake
duct.
Refer to "JET PUMP UNIT" in Chapter
6.
Measure the clearance at each impel-
ler blade as shown (a total of three
measurements).
Install the intake duct and intake grate.
Refer to "JET PUMP UNIT" in Chapter
6.
Install the battery leads.
3-14