Trouble shooting

Problem
ON / OFF switch is turned
off
Washer is not
Damaged power supply
operating
cable
Mains fault
Air trapped in the pressure
Washer does
washer
not generate
any pressure
Drop in the water mains
pressure
Severe pressu-
High-pressure nozzle is dirty
re fluctuations
12
Possible cause
Remedy
Check ON / OFF switch
Check power supply cable for da-
mage. If necessary have the power
supply cable replaced by a qualified
electrician.
Check the electrical system for confor-
mity with the data on the rating plate.
Turn on the washer with high-pressu-
re hose until bubble-free water flows
out of the high-pressure connection.
Check the water mains.
Rinse the high-pressure nozzle with
water. If necessary clean the nozzle
hole with a needle.