PEDESTAL FIXING Fig.1
The filter pump must be vertically fixed on ground or a certain pedestal made of
wood or concrete before use. There should be two holes 9mm in diameter on the
pedestal, the space between which should be 212mm. Put filter pump on the
pedestal and fix them together by fasten the bolts and nuts. All the pedestal parts
should weigh over 18kgs at least to prevent the pump from accidental falling.
Operation
1) Open/unscrew the Air Purge Valve (P6112 and P6030) on the top of the Filter Pump; air is released as water fills the Filter Pump.
2) When water comes out of the Air Purge Valve (P6112 and P6030), screw it closed and wipe away any water.
3) To start the Filter Pump, insert the plug into a residual current device (RCD).
4) Turn on the switch to the "I" position.
RCD Test
A. Insert the plug into the power outlet.
B. Press the "RESET" button; the indicator light turns red.
NOTE: If the indicator light is not on, the test has failed.
C. Press the "T" button; the indicator light turns off.
NOTE: If the indicator light is not off, the test has failed.
D. Press the "RESET" button, the indicator light turns red.
E. Unplug the pump, and the pump is ready for use.
WARNING: RISK OF ELECTRIC SHOCK. The RCD plug must
be tested before each use.
WARNING: Do not use the pump if this test fails. Please contact
your local Bestway Aftersales Service.
WARNING: Insert the RCD plug into a residual current device
A
RESET
TEST
Fig.1
B
RESET
TEST
6
2-M8 nut
2-M8 bolt
C
RESET
TEST
D
S-S-004242