Safety
Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation
Instructions
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The fittings must be mounted in an insulated manner
and with sound insulation.
• Mount the body in such a way, that the outlet faces
to the top and that the marking on the protective
cover is flush with the face of the tiling.
• Depth of fitting: 56 mm to 84 mm.
• Note: When installation is complete ensure that the
mixer is turned off!
Technical
Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Connections Rp 1/2:
The product is exclusively designed for drinking water!
Symbol
description
Do not use silicone containing acetic acid!
Adjustment
(see page 33)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Dimensions
(see page 31)
Flow
diagram
(see page 31)
free flow
Spare
parts
(see page 32)
Special
accessories
(order as an extra)
extension set 28 mm
#32698000 (see page 32)
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 70°C / 4 min
cold right - hot left
English
Final
assembly
(see page 34)
Test
certificate
(see page 40)
65°C