Setting the timer
Setting the Timer in Manual Mode (24-hour timer)
1
Press the Auto/Manual mode button (19) to select the manual mode. The display
shows "M" in manual mode (7).
2
Press the "Set" button (13) to set the hour of the timer to stop the heating. Press the
up (10) and down (1 1) buttons to select the hour (if the selected hour is less than the
current hour, the system is automatically activated the next day).
3
Press the "Set" button (13) to set the minute of the timer to stop the heating (if the set
hour is identical to the current hour but the selected minute is less than the current
minute, the system is automatically activated the next day).
4
Press the "OK" button (12) to save and exit the timer setting. The system is stopped
at the time you set.
Setting the Timer in Auto Mode (Time Table Timer)
1
Press the Auto/Manual mode button (19) to select the Auto mode. The display
shows "A" in Auto mode (8).
2
Press the "Set" button (13) to set the working timer of the heater.
3
Press the up (10) and down (1 1) buttons to select the week setting date.
4
Press the "Set" button (13) again to set the first working timer of the day.
5
Press the up (10) and down (1 1) buttons to set the hour for the heating start.
6
Press the "Set" button (13) again and use the up (10) and down (1 1) buttons to
select the stop date of the heating.
7
Press the "Set" button (13) to confirm the first period. The set stop time appears in
the day of the week display (18). There are 4 working hours per day.
8
Repeat the above procedure to set the working time for other time periods (if the
start time matches the stop time, the system cancels this heating phase).
Power on and off
• Press the start/stop button (20) to turn the heater on or off. If you exit the system
while it is in automatic mode, it will work according to the default procedure.
• However, if it is to remain off for a long time, you must switch the system to manual
mode and then off. If the system is outside the preset working time, it switches off in
1 second after pressing the start/stop button (20) without any action.
Part power and full power choose
• Press the heating power button (2) to change the power to partial or full load.
• At full load, full heating capacity (5) is shown in the display and half heating
capacity (4) shows "LO".
• In the case of partial load, "LO" is activated in the display half heating capacity (4)
and "HI" is deactivated in the display full heating capacity (4).