Herunterladen Inhalt Inhalt Diese Seite drucken

Husqvarna HMI:FS5000 D Bedienungsanweisung Seite 13

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Message on the
Fault code
display
C1D0615
Water pump
C1D0611
Water pump
C1D0915
Working light
C1D0911
Working light
C1D0C15
Ignition
C1D0C11
Ignition
1247 - 001 - 09.07.2019
DTC description
Circuit short to battery
or open
Circuit short to ground
Circuit short to battery
or open
Circuit short to ground
Circuit short to battery
or open
Circuit short to ground
Indication on the ma-
chine
Water pump can not
be controlled by the
HMI. May not be able
to turn on.
Water pump can not
be turned on.
Working light can not
be controlled by the
HMI. May not be able
to turn on.
Engine can not be
started.
Possible action
Check K2 in relay/fuse box.
Check damage to X14 con-
nector, harness to relay/fuse
box and relay/fuse box con-
nector. If found, repair and re-
start system, reset fault code.
If problem still exists, contact
your service agent for further
information.
Check working light relay K3 in
relay/fuse box.
Check damage to X14 con-
nector, harness to relay/fuse
box and relay/fuse box con-
nector. If found, repair and re-
start system, reset fault code.
If problem still exists, contact
your service agent for further
information.
Yanmar:
Check K8 in relay/fuse box.
Check damage to X14 con-
nector, harness to relay/fuse
box and relay/fuse box con-
nector. If found, repair and re-
start system, reset fault code.
If problem still exists, contact
your service agent for further
information.
Deutz:
Check damage to X14 and X1
connector and harness. If
found, repair and restart sys-
tem, reset fault code.
If problem still exists, contact
your service agent for further
information.