Dispose of the old oil at a drop-off point
for old oil.
To fi ll in the correct quantity of oil, make sure that
the compressor stands on an even surface. Fill
new oil through the oil fi ller opening (21) until it
comes up to the maximum level. This is marked
with a red dot on the oil level window (18) (Figure
1 1). Do not exceed the maximum fi lling quantity.
Overfi lling the equipment may result in damage.
Reinsert the oil sealing plug (16) into the oil fi ller
opening (21).
9.6 Cleaning the intake fi lter
(Fig. 2, 3, 12)
The intake fi lters (15) prevent the drawing in
of dust and dirt. It is essential to clean these
fi lters after at least every 300 hours in opera-
tion. A clogged intake fi lter will decrease the
compressor's performance dramatically.
Remove the intake fi lters from the equipment by
unscrewing them. The fi lter housing (D) is plugged
on the fi lter cover (C) and can be removed by ap-
plying slight pressure to the fi lter cover. Carefully
tap out the air fi lters (F), the fi lter cover and the
fi lter housing. Then blow out these parts with com-
pressed air (approx. 3 bar) and reinstall in reverse
order. The fi lter cover and the fi lter housing have
different latching positions. When you assemble
the intake fi lter, make sure that the intake opening
faces down.
9.7 Storage
Important!
Pull out the mains plug and ventilate the
equipment and all connected pneumatic
tools (see 9.7.1). Switch off the compres-
sor and make sure that it is secured in
such a way that it cannot be started up
again by any unauthorized person.
Important!
Store the compressor only in a dry lo-
cation which is not accessible to unau-
thorized persons. Always store upright,
never tilted! Oil may leak out!
Anleitung_4010411_LB2.indb 56
Anleitung_4010411_LB2.indb 56
GB
9.7.1 Releasing excess pressure
Release the excess pressure by switching off the
compressor and using the compressed air which
is still left in the pressure vessel, e.g. with a com-
pressed air tool running in idle mode or with a
blow-out pistol.

9.8 Ordering replacement parts:

Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
For our latest prices and information please go to
www.isc-gmbh.info
9.9 Transport (Figure 1)
Switch off the equipment and pull out the
power plug before lifting and moving the
compressor.
Use the transport handle (1) to move the com-
pressor.
Use the transport handle (1) and the grip (12)
on the pressure vessel (7) to lift the compres-
sor. Note the equipment's weight!
Transport the compressor only in an upright
position and secure it against tilting so that no
oil runs out.
Secure the compressor in accordance with the
regulations in force for transporting equipment
in motor vehicles.

10. Disposal and recycling

The unit is supplied in packaging to prevent its
being damaged in transit. This packaging is raw
material and can therefore be reused or can be
returned to the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic. De-
fective components must be disposed of as spe-
cial waste. Ask your dealer or your local council.