Herunterladen Inhalt Inhalt Diese Seite drucken

How To Use; Maintenance And Inspection - Hitachi D 10DD Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
English

HOW TO USE

CAUTIONS
While operating the driver drill, take care not to lock
the motor.
If the motor is locked, immediately turn the power
off.
If the motor is locked for a while, the motor or
battery may be burnt.
1. Switch lock and switch
To operate this tool, first release the switch lock.
(See Fig. 9)
When the trigger switch is depressed, the tool
rotates. When the trigger is released, the tool stops.
The rotational speed of the drill can be controlled
by varying the amount that the trigger switch is
pulled.
Speed is low when the trigger switch is pulled
slightly and increases as the switch is pulled more.
(D10DG only.)
After use, always lock the switch. (See Fig. 9)
This prevents the tool from rotating unexpectedly.

MAINTENANCE AND INSPECTION

1. Inspecting the tool
Since use of as dull tool will degrade efficiency and
cause possible motor malfunction, sharpen or
replace the tool as soon as abrasion is noted.
2. Inspecting the mounting screws
Regularly inspect all mounting screws and ensure
that they are properly tightened. Should any of the
screws be loose, retighten them immediately. Failure
to do so could result in serious hazard.
3. Cleaning on the outside
When the driver drill is stained, wipe with a soft
dry cloth or a cloth moistened with soapy water.
Do not use chloric solvents, gasoline or paint thinner,
for they melt plastics.
4. Storage
Store the driver drill in a place in which the
temperature is less than 40°C and out of reach of
children.
NOTE
Due to HITACHI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.
8
IMPORTANT
Correct connection of the plug
The wires of the mains lead are coloured in accordance
with the following code:
Blue:
Brown:
As the colours of the wires in the mains lead of this
tool may not correspond with the coloured marking
identify ing the terminals in your plug proceed as
follows:
The wire coloured blue must be connected to the
terminal marked with the letter N or coloured black.
The wire coloured brown must be connected to the
terminal marked with the letter L or coloured red.
Neither core must be connected to the earth terminal.
NOTE
This requirement is provided according to BRITISH
STANDARD 2796: 1984.
Therefore, the letter code and colour code may not be
applicable to other markets except United Kingdom.
Information concerning airborne noise and vibration
The measure values were determined according to
EN50144.
The typical A-weighted sound pressure level does not
exceed 70 db (A).
Wear ear protection.
The typical weighted root mean square acceleration value
does not exceed 2.5 m/s
– Neutral
– Live