en | System Test
16
4

System Test

4.1

Siren Test

This function allows the code holders to test the siren.
a) Enter your Code + [4] [1] and press [#]. It beeps twice and the siren will be activated for 1
second.
4.2

Communication Test

This function allows the code holders to send a test report to a central monitoring station.
a) Enter your Code + [4] [2] and press [#]. It beeps twice and a test report is send.
The Keypad will display the status of the test report for all communication paths.
To exit the test report press [#].
4.3

Walk Test Mode

This function allows code holders to test detection devices to ensure they are functioning
correctly. Before activating Walk test Mode, bypass any zones that are not required for testing.
During the walk test, no walk test report is sent out to the control panel system.
How to enter into Walk Test Mode:
1.
2.
To exit Walk test Mode:
1.
2013.07 | 03 | F.01U.267.114
Enter your Code + [4] [3] and press [#]. It beeps twice and the STAY and AWAY indicators
flash.
Unseal and seal the zones to be tested. The keypad sounds one second beep and the
siren sounds one beep each time when a Zone status is changed.
Enter your Code + [4] [3] and press [#].