Herunterladen Inhalt Inhalt Diese Seite drucken

Preparatory Steps: Backing Up Device Data; Applicable Documentation - Endress+Hauser Promag 50 Einbauanleitung

Replacing the transmitter
Vorschau ausblenden Andere Handbücher für Promag 50:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EA00059D
7

Preparatory steps: backing up device data

ConversionPromag 50
Read out important device parameters from the application (e.g. using the
"Commissioning" quick setup, Operating Instructions for the device), and enter them in
the parameter list in section 9 →  13. Following conversion, enter the noted
parameters in the new transmitter.
ConversionPromag 53
Saving transmitter parameters to the T-DAT using the "T-DAT SAVE/LOAD" function.
Description of Device Functions or Operating Instructions, "Commissioning" section →
data backup with "T-DAT save/load. After modifying the device, insert the T-DAT into
the transmitter.
7.1
Overview of data storage (Histo-ROM) and F-CHIP
Data storage
Color
medium
S-DAT
Blue
T-DAT
Black
F-CHIP (optional) Red
7.2

Applicable documentation

The documentation that applies to the transmitter is the documentation for the Promag
55.
The documentation that applies to the sensor is the documentation for the Promag 50,
53.
7.3
Conversion-related modifications and restrictions
Accuracy
Following conversion of the device, an additional inaccuracy of ± 0.2% of the measured
value is to be expected.
8
Promag 50 remote version
to Promag 55 remote version
Reinstallation
New
New
Promag 53 remote version
to Promag 55 remote version
Reinstallation
Reinstallation
New
Endress+Hauser

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Promag 55Promag 53

Inhaltsverzeichnis