9.2.1 Water hardness

Set to 1750 at the factory!
i
1. Simultaneously press the
seconds.
CAUTION!
If
is displayed, press no further
buttons (test mode manufacturer)!
Wait for approx. 10 seconds until the current
time is redisplayed!
2. Enter the calculated set value via the
buttons.
3. Press the
button once to go to the next setting.
9.2.2 Regeneration
Note:
In operation or water consumption the residual capaci-
ty is reduced from the set amount to zero.
Residual volume 530 litres Residual volume 0 litres
Time-delayed, volume-controlled regeneration
Regeneration is triggered at the set time.
Set to 2.00 a.m. at the factory!
i
Input: 24-hour mode
Time regeneration
1. Press the
and
2. Press the
button once to go to the next setting.
Forced regeneration
Note:
If the programmed number of days between two rege-
nerations has been reached, a forced regeneration is
triggered at the set time. The forced regeneration is
triggered irrespective of the residual volume.
Set to 14 days at the factory!
i
Input: OFF up to 99 days
Forced regeneration
1. Press the
and
ber of days.
2. Press the
button once to accept all the chan-
ges.
MU1H-1408GE23 R0305
and
buttons for 5
and
buttons to change the time.
buttons to change the num-
GB

Manual regeneration

There are two manual regeneration possibilities avai-
lable.
1. Possibility
1. Press the
button for 5 seconds.
Manual regeneration starts immediately.
2. Possibility
1. Press the
button for a short time.
Manual regeneration starts at the set time
( Chapter 9.2.2)
LED operating display flashes( Chapter 8.1)
i
Change to the next regeneration phase
1. Press the
button once to go to the next regene-
ration phase..
If the water conditioning device is in between two
phases, pressing the button has no effect.

10. Power Failure

10.1Settings

The time has to be reentered after a power failure
Chapter 9.1.
All the control valve settings remain and are restored
once the power supply has been reconnected.

10.2General Information

If the power is down for a longer period, the water con-
ditioning device should be set to "Bypass"
( Chapter 8.4)