8. Operation

8.1 Control Buttons, Display and Indicators

Service indicator
LED on:
Valve in service
LED flashing:
Regeneration on set time
( Chapter 9.2.2)
Program indicator
Program mode entered
( Chapter 9.2)
Regeneration
button
Reverse rinsingn
LED on: active phase

8.2 Display during Operation

During normal operation the time and residual capacity
are displayed alternately.

Time

8.3 Display during Regeneration

During regeneration the active regeneration phase is
displayed. In addition to the phase number the remai-
ning time of the active regeneration phase is also dis-
played. After all 4 regeneration phases have been
completed, the water conditioning device returns to
normal operation.
Regnereration Phase 2, Remaining time 27 Minutes
8.4 "Bypass" function
8.4.1 "Bypass" position (Fig. 3)
In this position the raw water is not treated in the water
conditioning device.
The raw water runs, via the bypass valve, through the
connection adaptor back into the drinking water supply.
8.4.2 "Service" position (Fig. 3)
In this position the raw water is treated in the water
conditioning device.
Honeywell GmbH
Slow rinse
LED on: active phase
Residual volume (litres)
GB
4
Brine refill
LED on: active phase
Rapid rinse
LED on: active phase
8.4.3 Start-Up operation
For the first 1-2 week running period the brand-new
water conditioning device is in start-up operation.
During this period noise development can occur during
regeneration but will automatically disappear after ap-
prox. 1-2 weeks.

9. Settings

9.1 Time
Input: 24-hour mode
i
1. Set the time via the
The clock runs quicker when the
tons are held pressed.
Time

9.2 Control valve

All settings at the control valve have to be ente-
i
red in the check list!
WARNING!
Incorrect parameter changes can lead to sub-
stantial property damages!
In order to accept changes for the control valve
i
settings, run the programming until the end
proceed with the
15
Flow indicator
LED flashing: Water flow
Setting buttons
Set value
downwards
Set value
upwards
and
buttons.
and
but-
button!
MU1H-1408GE23 R0305