Inputs

There is an operating voltage input (15), an input for connecting a rechargeable battery (LiPo,
14), an analogue input (16) and an opto coupler (17).
Observe the maximum input voltage of 2.8V at the ADC and the maximum input
voltage of 32V DC at the opto coupler input and operating voltage!

Outputs

Each output has its own LED to indicate its current status. The first output (19) is already
connected to a relay.
Observe the relay connection data (5 A at 30 V DC or 8 A at 250 V AC).
At the second output (18), there is a switching output of 32 V/DC and 300mA.
You can directly connect a relay to this output (e.g. Conrad order no. 502892).
The relay must only be connected by a specialist. The device must be powered
down before it is opened.

Aerial

The "GX107" has an integrated aerial. If reception is too bad or the "GX107" must be positioned
in a place with bad reception, you may connect an external aerial (Conrad order no. 199399).
Aerials with a MMCX plug can be connected inside of the casing (20). You should first check
the receiver quality at the intended application site with a mobile phone.

SIM Card

The SIM card is inserted into the holder on the front of the circuit board (see section on
"Preparation of the SIM Card")

GPS

An external GPS module can be connected to the 6 pole connection (13) on the circuit board
(Conrad order no. 199310). The GPS module serves simple determination of the location of
the "GX107", but can also be used for object monitoring (see section on "GPS Use and Setup").
56