7. Operating Conditions

Only operate the module with an operating voltage between 5 and 32 Volt DC and observe the
polarity. The power source must supply at least 700 mA.
The maximum switching output of the relay (OUT1) is 5 A at 30 V DC or 8 A at 250 V AC.
The maximum switching output of the transistor output (OUT2) is 300 mA at 32 V/DC.
When installing the module, ensure a sufficient cable cross-section of the connection lines.
The module may be operated in any position.
To ensure the function as "GX107", select an installation site that allows access to the GSM
net. The location must not be screened by e.g. reinforced concrete walls, metal-coated mirrors,
metal shelves, etc.
Optionally, you may use an external aerial (available as an accessory).
There should be no devices with strong electrical fields such as mobile telephones, walkie-
talkies, electric motors etc. in the vicinity of receiver.