Error messages

In case of any defects, an error message appears on the display. Follow the directions supplied or contact an authorized dealer.
Fault
Error message
Code
F01
MOTOR OVERHEATED
F02
POWER PACK OVERHEATED
F03
LOW VOLTAGE
F04
HIGH VOLTAGE
F05
OVER CURRENT
F06
NO HALLSENSOR LENGTH
F07
NO HALLSENSOR ARM
F08
TRAVEL MOTOR OVERLOADED Travel motor overloaded.
F09
DEPTH MOTOR OVERLOADED
F10
BLADE JAM
GROUND FAULT OR NO SAW
F11
HEAD
F12
NON-COMPATIBLE SAW UNIT
NO CONTACT CHECK CAN-
F13
CABLE
F14
NO RADIO CONTACT
F15
NO DSP RESPONSE
MAINTENANCE
Cause
Water coolant lacking/
insufficient to saw motor.
Water coolant lacking/
insufficient to power pack.
Low voltage supply to the
power pack.
High voltage supply to the
power pack.
Over current to saw motor
Fault on HALL-sensor card
for travel feed
Fault on HALL-sensor card
for depth feeding
Depth motor overloaded.
Blade can not rotate.
Incorrect earthing of power
pack/saw or no saw unit
connected to the power
pack.
Incorrect saw unit connected
to the power pack.
No contact between power
pack and remote control
No radio contact between
remote control and power
pack.
Internal error in the power
unit.
Steps
Check that the water coolant flows to the saw motor
and that it is max. 25ºC and min 3.5 l/min.
Check that the water coolant flows to the power pack
and that it is max 25°C and min 3.5 l/min. If the
message pops up when the blade rotation is started -
go to the operations menu and "Water coolant" and
select "ON". Let the water coolant circulate the power
pack for a minute before you turn the blade rotation on
again.
Check the voltage during operation. Check that all
three phases exist. Check that incoming cables have
sufficient cross-sectional area.
Check the voltage during operation. This message is
shown mainly when using a generator as power
source.
Check that the power lead is fitted correctly and that it
is not damaged. The message can appear in case of
a loose contact.
Take the equipment to an authorized service shop.
Take the equipment to an authorized service shop.
Turn the lever to the 0 position to reset. If the fault
message recurs, it may be because the diamond tool
is not sharp enough or because the saw carriage is
not adjusted correctly. Grease also the feeder gears
and clean the rails. If these measures do not help,
hand in the equipment to an authorized Husqvarna
service workshop.
Turn the lever to the 0 position to reset. If the fault
message recurs, it may be because the diamond tool
is not sharp enough or because the saw carriage is
not adjusted correctly. Grease also the feeder gears
and clean the rails. If these measures do not help,
hand in the equipment to an authorized Husqvarna
service workshop.
Remove the blade from the cut and start the blade
rotation.
Check the incoming electrical connection to the power
pack and that the saw unit is connected to the power
pack. If this does not help, hand in the equipment to an
authorized Husqvarna service workshop.
Connect a compatible saw unit to the power pack.
Replace the CAN-cable.
Check that the power pack is activated and that the
green indicator light is on. If this does not help, hand
in the equipment to a Husqvarna service workshop.
The machine can be used with the CAN cable
between the power pack and remote control.
Take the equipment to an authorized service shop.