13. Possible causes of failure

Problem
The compressor does not
start
The compressor starts but
there is no pressure
The compressor starts,
pressure is shown on the
pressure gauge, but the tools
do not start.
26
08.06.2007
9:58 Uhr
Cause
1. No supply voltage
2. Insufficient supply voltage
3. Outside temperature is too
low
4. Motor is overheated
1. Leak in the non-return valve
(16)
2. The seals are damaged.
3. Leak in the drain valve (18)
1. Loose hose connections
2. Leak in a quick-lock coupling 2. Check the quick-lock
3. Insufficient pressure set on
the pressure regulator.
Seite 26
Solution
1. Check the supply voltage,
the power plug and the
socket-outlet.
2. Make sure that the extension
cable is not too long. Use an
extension cable with large
enough wires.
3. Never operate with an
outside temperature of below
+5°C.
4. Allow the motor to cool
down. If necessary, remedy
the cause of the overheating.
1. Replace the non-return valve
2. Check the seals and have
any damaged seals replaced
by a service center
3. Tighten the screw by hand.
Check the seal on the screw
and replace if necessary.
1. Check the compressed air
hose and tools and replace if
necessary.
coupling and replace if
necessary.
3. Tighten the pressure
regulator further or connect
the hose to the coupling for
unregulated tank pressure.