Select your zone (armzone 05 up to armzone 12). Zones 1 through 4 are reserved for wired sensors
(terminal 5 ~ terminal 8 onto the PCB). Confirm with the # button. Following message will be
displayed:
Next, activate the sensor. The central will emit a short beep and display the previous menu. The
sensor has been assigned to its zone. Repeat previous steps to assign more sensors.
Submenu 3 – Del
The Del menu is used to erase all saved remote controls and sensors.
h. Alarm Messages through the Telephone
The central unit will dial the programmed telephone numbers when the alarm is triggered. Short beeps will
be heard (the number depends on the number programmed in "dial times"). The user will hear the vocal
message upon answering the telephone. Press the # button on the telephone to make the central unit stop
calling.
i. Remotely Controlling the Central Unit
The central unit can be remotely switched on and off. To do so, dial the number of the telephone line
connected to the unit. The alarm unit will answer the call after the number of rings programmed in "vibrant
ring". Press the user code first and confirm with #, followed by:
1 to enter the ARM mode
2 to enter the DISARM mode
3 to listen to built-in microphone of the central unit
4 to cancel the call.
8. Commands on the Remote Control and the Help Alarm
Refer to the illustrations on page 2 of this manual.
•
The 4-key remote control will be encoded automatically. The commands can be used as soon as the remote
control is saved into the system:
•
[R1] DISARM: alarm system deactivation
•
[R2] HOME ARM: entering the HOME or GUARD mode
•
[R3] AWAY ARM: entering the AWAY mode
•
[R4] HELP: panic function activation (push upwards to activate)
Remark: Follow these steps to assign a different code when 2 or more remote controls have been encoded
similarly:
Open the remote control by unscrewing the screw at the back. Remove the battery. Hold any key on the
remote control pressed and reinstall the battery. The LED on the remote control will blink. Release the
pressed key. The remote control has learned a new address. Close the remote control and reprogram into
the system.
•
Press the panic button on the help remote [A1] three times to activate the panic alarm.
9. The PIR Sensor
Refer to the illustrations on page 2 of this manual.
•
Open the motion sensor by unscrewing the 3 screws at the back.
P1
sense time interval
P2
mode selector
P3
coding switch
P4
sense LED (green)
•
The PIR sensor can detect motion in 2 ways. By setting the jumper [P2] in the first mode (1x) the sensor
will trigger the alarm immediately after detecting motion. By setting the jumper in the second mode (2x) the
sensor will wait for a second motion detection after the first one. This mode can be used to reduce the
detection of motion caused by house pets.
•
In the second mode, set the time interval by turning the sense time interval switch [P1] (max. ±150s.).
•
Install a 9V battery (incl.). Wait for ± 60 seconds until the sensor has stabilised.
•
Press the code switch [P3] to send an address code for the sensor to the alarm unit. The green LED [P4]
flashes quickly. Make sure the sensor does not detect movement during this initialization (e.g. cover the
sensor [P7]). When initialization is completed, the green LED [P4] starts flashing slowly.
•
When motion is detected by the PIR sensor [P7], the red LED [P5] turns on.
•
To switch off LED feedback, remove the LED jumper [P6].
18.04.2017
HAM06WS
be studying
*
P5
transmit LED (red)
P6
LED on/off jumper
P7
PIR sensor
9