Elektroschaltplan - Komponenten: Innengerät - Daikin ERLQ006CA Referenzhandbuch

Vorschau ausblenden Andere Handbücher für ERLQ006CA:
Inhaltsverzeichnis

Werbung

15 Technische Daten
15.6.2 Elektroschaltplan – Komponenten: Innengerät
Siehe mitgelieferten Innen-Schaltplan (Innenseite der Abdeckung des Schaltkastens der Inneneinheit). Nachfolgend sind die verwendeten
Abkürzungen aufgeführt:
NOTES to go through before starting the unit
X1M
: Main terminal
X2M
: Field wiring terminal for AC
X5M
: Field wiring terminal for DC
: Earth wiring
15
: Wire number 15
: Field supply
**/12.2
: Connection ** continues on page 12 column 2
1
: Several wiring possibilities
: Option
: Wiring depending on model
Backup heater
3V3 (1N~, 230 V, 3 kW)
configuration
6V3 (1N~, 230 V, 6 kW)
(only for *9W)
6WN (3N~, 400 V, 6 kW)
9WN (3N~, 400 V, 9 kW)
6T1 (3~, 230 V, 6 kW)
User installed options:
Bottom plate heater
Domestic hot water tank
Domestic hot water tank
with solar connection
Remote user interface
Ext. indoor thermistor
Ext. outdoor thermistor
Digital I/O PCB
Demand PCB
Solar pump and control station
Main LWT:
On/OFF thermostat (wired)
On/OFF thermostat (wireless)
Ext. thermistor
Heat pump convector
Add LWT:
On/OFF thermostat (wired)
On/OFF thermostat (wireless)
Ext. thermistor
Heat pump convector
Referenzhandbuch für den Monteur
89
X6M, X7M
: Backup heater terminal
X4M
: Booster heater terminal
: Not mounted in switch box
: PCB
POSITION IN SWITCH BOX
Q1L
A7P
X6M
X7M
TR1
K1M
K2M
K5M
K3M
A1P
X6Y
F1B
F2B
X5M
X2M
A8P
X1M
X4M
A4P
Translation can be found in the installation manual.
Part n°
Description
A1P
main PCB
A2P
user interface PCB
A3P
solar pumpstation PCB
*
A3P
On/OFF thermostat (PC=power circuit)
*
A3P
heat pump convector
*
A4P
digital I/O PCB
*
A4P
receiver PCB (wireless
*
On/OFF thermostat)
A7P
pump driver PCB (only for *16*)
A8P
demand PCB
*
B1L
flow sensor
BSK
solar pump station relay
*
DS1 (A8P)
dipswitch
*
E1H
backup heater element (1 kW)
E2H
backup heater element (2 kW)
E3H
backup heater element (3 kW)
E4H
booster heater (3 kW)
*
F1B
overcurrent fuse backup heater
F2B
overcurrent fuse booster heater
*
F1T
thermal fuse backup heater
F1U, F2U
fuse 5 A 250 V for digital I/O PCB
*
FU1
fuse T 6.3 A 250 V for PCB
PHC1
optocoupler input circuit
*
K1M, K2M
contactor backup heater
K3M
contactor booster heater
*
K5M
safety contactor BUH (only *9W)
K*R
relay on PCB
M1P
main supply pump
LEGEND
M2P
#
domestic hot water pump
M2S
#
2 way valve for cooling mode
M3S
(*)
3 way valve for floorheating/
domestic hot water
Q1DI, Q2DI
#
earth leakage circuit breaker
Q1L
thermal protector backup heater
Q2L
thermal protector booster heater
*
R1T
outlet water heat exchanger thermistor
R1T (A2P)
ambient sensor user interface
R1T (A3P)
ambient sensor On/OFF thermostat
*
R2T
outlet backup heater thermistor
R2T
external sensor (floor or ambient)
*
R3T
refrigerant liquid side thermistor
R4T
inlet water thermistor
R5T
(*)
domestic hot water thermistor
R6T
external indoor or outdoor
*
ambient thermistor
R1H (A3P)
humidity sensor
*
S1S
#
preferential kWh rate PS contact
S2S
#
electrical meter pulse input 1
S3S
#
electrical meter pulse input 2
S6S-S9S
#
digital power limitation inputs
SS1 (A4P)
selector switch
*
T1R (A7P)
rectifier bridge (only for *16*)
TR1
power supply transformer
X*M
terminal strip
X*Y
connector
* : optional
(*) : standard for *HV*, optional for *HB*
# : field supply
4D077028 page 1
EHBH04+08 + ERLQ004~008
Daikin Altherma - Niedertemperatur Split
4P313774-1 – 2012.05