Herunterladen Inhalt Inhalt Diese Seite drucken

Velleman CU2200 Bedienungsanleitung Seite 11

Drahtloser sms-alarm
Vorschau ausblenden Andere Handbücher für CU2200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

System Version Check (hardware version CU2200)
Software version V6
Command: PWD:XXXX,CHECKV
[SMS message received]
ex: SD41 V5.1_3_B 2008/01/28
V5 is system version or hardware version
CU2200.
Return Message
Command succeeds
SMS message: Function Code & Setting Parameters Set in the command
Command fails
SMS message: SMS Format is error!
System Parameters Report
Command: PWD:XXXX,PARAMETER1%
[SMS message received]
ST:XXX;T:2006/10/08/08:00;H:X;F1:XXXXXXXXXXX,YY;F2:XXXXXXXXXXX,YY;XH:RR;ER:xyz#
ST:
T:
H:X
F1
XXXXXXXXXX
YY
XH:RR
ER:xyz
Command: PWD:XXXX,PARAMETER2%
About the alarm channel
[SMS message received]
ST:XXX;VL:XXXXX,O:AX,BBBBBBBB,CCC:A1M:XXXXX,UUUUU,YYYYY,R,HHHHH,PPPPP,O:AX,BBBBB
BBB,CCC;A2M:XXXXX,UUUUU,YYYYY,R,HHHHH,PPPPP,O:AX,BBBBBBBB,CCC;#
VL
A
X
BBBBBBBB
CCC
Command: PWD:XXXX,PARAMETER3%
About the alarm 1 ~ 8 status
[SMS message received]
ST:XXX;K1:N,O:AX,BBBBBBBB,CCC;K2:N,O:AX,BBBBBBBB,CCC;K3:N,O:AX,BBBBBBBB,CCC;K4:N,
O:AX,BBBBBBBBB,CCC;K5:N,O:AX,BBBBBBBB,CCC;K6:N,O:AX,BBBBBBBB,CCC;K7:N,O:AX,BBBBB
BBB,CCC;K8:N,O:AX,BBBBBBBB,CCC;OTY:0000,0000,0000;#
K1
N
O
A
23.10.2014
CU2200
Unit serial number
Date/time
Arm/disarm
1
st
control centre number
Control centre number
Automatic health report schedule
GSM network signal strength (1 ~ 40)
GSM Module
SIM Card/Service
GSM Network Coverage
Min. operating voltage (7VDC by default), alarm will be triggered if
voltage drops below this level
Alarm report to control centre 1
0 means no report
1 means report
Alarm report to control centre 2
0 means no report
1 means report
Report status for 8 phone numbers
0 means no report
1 means SMS but no phone dial
2 means phone dial but no SMS
3 means SMS first and then phone dial
Relay output control
0 means control not triggered by alarm
1 means alarm triggered control
Alarm channel 1
0 means disabled
1 means closed triggered alarm
2 means open triggered alarm
3 means both closed and open triggered alarm
Corresponding output relay status
Alarm report to control centre 1
0 means no report
1 means report
Software version V7
Command: PWD:XXXX,CHECKVR%
[SMS message received]
ex: SD41 V7.1_3_B 2010/01/28
V7 is system version or hardware version
CU2200.
Normal
x
0
y
0
z
0
11
v
3-03
Defect
1
1
1
©Velleman nv

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis