Herunterladen Inhalt Inhalt Diese Seite drucken

Welding; Overheat Protection; Maintenance - Parkside PESG 120 B3 Montage-, Bedienungs- Und Sicherheitshinweise Originalbetriebsanleitung

Elektro-schweißgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
Preparing to weld / Welding / Overheat protection / Maintenance
emitted by the arc, yet allows for a clear view
of the work piece.

Welding

After making all the electrical connections for the
power supply and for the welding circuit, proceed
as follows:
Insert the uncoated end of the electrode into
the electrode holder
terminal
to the work piece. Be sure the
4
electrical contact is good.
The device features a latch for setting the plate
thickness. Switch on the device by setting the
ON / OFF switch
2
use the hand wheel
thickness: For 1.6 or 2.0 mm electrodes set the
hand wheel
to position 1.6 / 2.0. For 2 mm
3
electrodes set the hand wheel
Hold the welding shield
and guide the tip of the electrode over the work
piece as if trying to light a match. This is the best
method for sparking the arc.
Use a test piece to check if you selected the
correct electrode and current.
ATTENTION!
Do not dab the work piece with the electrode. It
could become damaged and make it more difficult to
spark the arc. Once the arc is sparked, try to main-
tain a distance to the work piece appropriate for the
selected electrode diameter. Keep the distance as
consistent as possible whilst welding. The electrode
grade in the work flow direction should be 20–30
degrees.
ATTENTION!
Always use forceps to dispose of used electrodes or
move hot work pieces. Please remember to always
place the electrode holder onto an insulating pad
after welding.
Only remove slag once the seam has cooled. If
continuing to weld on an interrupted weld seam,
first remove the slag at the start of weld.
28 GB/IE
and connect the earth
5
to the "ON" position. Then
to select the electrode
3
to position 2.5.
3
in front of your face
7
ATTENTION!
Welding produces heat. The welding equipment
must therefore be operated in open loop after use
for at least half an hour. Or alternatively allow the
equipment to cool off for one hour. Only pack up
and store the equipment once the equipment tem-
perature has normalised.
Switch the equipment off by setting the ON /
OFF switch
to the "OFF" position.
2

Overheat protection

The welding equipment features overheat protection.
If the overheat protection is triggered, the control
light
will light up. Allow the welding equipment
6
to cool down for a while.
PESG 120 B3 (with AC 230 V 50 Hz power plug):
The supply line fuses to the mains sockets must meet
the requirements (VDE 0100). Earthed wall sockets
must be protected with max. 16 A (model and tech-
nical data: NDM1-63, AC 230 / 400 V C16.
IEC 60898.time lag. Manufacturer: Nader) (fuses
or line circuit breaker). Higher fuse ratings can result
in burnt wires or fire damage to the building.
Attention: The equipment must be connected to
a mains source with the fuse rating specified above.
If the electrode holder and earth terminal is short
circuited, the fuse can be triggered in 16–20 seconds.
Classification per EMV standard: Class A per IEC
60974-10
Warning: Equipment categorised Class A are
intended for industrial use. When used in other
areas, electromagnetic tolerance may not be war-
ranted or failures may occur.

Maintenance

Regularly clean dust and dirt off the equipment.
Clean the equipment with a fine brush or a dry
cloth.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis