Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specification - Velleman SOL30UC12V Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SOL30UC12V:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

8.
Troubleshooting
Problem
Charging not
1. Reverse polarity
indicated on
2. Loose connection
display when
3. Not enough sunlight
solar panel is
connected
No output on
1. Load switch off
load
2. Battery not connected,
connections
loose connection or wrong
polarity.
3. Polarity load reversed
4. Over-discharge protection
enabled
5. Short circuit or overload
protection enabled
9.

Technical Specification

Solar input current (max.)
Load current (max.)
Solar input voltage (max.)
Over-charge protection
Over-discharge protection
Rated output voltage
open circuit voltage (max.)
No-load current
Voltage loss charging circuit
Voltage loss discharging circuit
control method
Operating temperature
25/11/2010
SOL30UC12V & SOL30UC24V
Battery voltage.
Load on/off switch [3] has no function.
Output current from battery to DC-load.
Indicates 0.00A when load is switched off.
Use the Load on/off switch [3] to switch the output current to the
load on or off.
Note: in over-discharge protection mode trying to switch on output
to the load will fail and a buzzer will sound. When the system
recovered from over-discharge protection mode (battery charge level
back to normal) press the Load on/off switch [3] 2 times to
restart output current to the load.
Charging current from solar panel to battery
Load on/off switch [3] has no function.
Possible cause
Possible solution
1. Correct polarity
2. Secure connection(s)
3. Reposition solar panel
1. Press switch [3]
2. Connect a battery to the regulator,
check correct polarity and secure
connection
3. Correct load polarity
4. Disconnect load and fully recharge
battery
5. Verify that load is not short circuited and
draws no more than 30A. Press switch [3]
when everything is OK.
SOL30UC12V
28V
14.5V±0.4V
10.7V±0.4V
12VDC
28V
<25mA
13.3V±0.4V
12V±0.4V
PWM charging
-25°C ~ 40°C
5
SOL30UC24V
30A
30A
50V
29.0V±0.5V
21.4V±0.5V
24VDC
50V
26.5V±0.5V
24.0V±0.5V
©Velleman nv
Rev. 04

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sol30uc24v

Inhaltsverzeichnis