Herunterladen Inhalt Inhalt Diese Seite drucken

Velleman HAMGSM133 Bedienungsanleitung Seite 13

Vorschau ausblenden Andere Handbücher für HAMGSM133:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Delete gate control phone numbers
Command:
DAC+YYnnnnnnnnnn;pwd
YY= country code
nnnnnnnnnn = phone number to delete
pwd = current password (default = 12345)
Example:
DAC+324851234567;12345
Disable reply SMS
Command:
RISP (commands)
Example:
RISP, OUT1:ON, DAC, INI1:10
10.
Managing via PC
Notes:
 To manage the HAMGSM133 with the aid of a computer (not incl.) a USB interface
(HAMGSM133/USB, not incl.) must be installed.
 Install the software on the PC prior to connecting the HAMGSM133 to the USB port.
 Computer port speed must be set to 9600 BAUD (8,N,1).
 When connected to a PC, managing via SMS is disabled.
Refer to the illustrations on pages 3, 4 and 5 of this manual.
Installing software
 Software can be downloaded from
 Install the software on the PC. Run the setup file and follow the instructions on the screen.
 When installation is completed, start the software. The configuration window [A] appears.
 Connect the HAMGSM133 to the USB port of the computer using an appropriate cable (not incl.).
 Select the desired COM port (top left). Click 'refresh' to rebuild the list of available ports.
 Click on 'Connect' (top centre) to activate the connection. When data is already present inside the
module, it will be shown.
 If no master number is available in the module, the "Waiting for Call for Master Number Storage"
message appears in the log window [B] (at the bottom of the screen). Make a call to the
HAMGSM133 before proceeding. A confirmation message is shown in the log window.
 The configuration window now shows a number of tabs.
o In the "Info" tab [C] you can find model number, firmware version and IMEI (International
Mobile Equipment Identity). It is also possible to change the password in this tab.
To be able to change the settings, enter the current password into the "system password" field
and click "Save".
If the device does not react to commands from the computer, make sure the password stored
in the PC is the same as the one specified in the management program.
o The "Phone Number" tab [D] is used to manage phone numbers. Store or delete numbers, or
request a full list (shown on the right). The overview window has two tabs, one for "Master
Numbers" [D] and another for "Gate Control Numbers" [E].
Each action must be confirmed.
o Use the tab "Notice" [F] to enable or disable numbers on specific positions in the list. Enable
to let them receive SMS or alarm calls.
o Configure the activation logic (high/low/switch-over) of the two inputs in the tab "Inputs" [G].
Check the "Request timing" checkbox and click "Run" to see the current settings in a pop-up
window [H].
o The "Outputs" tab [I] is used to control the relays manually.
 In every window it is possible to see an extended log showing all communication that goes
through the communication port. Click on "Enable extended LOG" at the bottom of the screen.
The extended log window pops up [J].
 Click on the question mark in the menu bar to see the current software version [K].
15/12/2011
Commands = series of commands separated by commas (,)
www.velleman.be
HAMGSM133
(password required)
13
© Velleman nv

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis