Herunterladen Inhalt Inhalt Diese Seite drucken

Velleman HAMGSM133 Bedienungsanleitung Seite 12

Duplex fernbedienungsmodul 2 in/2 out
Vorschau ausblenden Andere Handbücher für HAMGSM133:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Alarm SMS content when input 2 tension is high
Password
Command
Example
Result
Alarm SMS content when input 2 tension is low
Password
Command
Example
Result
Activate a relay output
Password
Command
Example
Result
Deactivate a relay output
Password
Command
Example
Result
Invert the condition of a relay for a certain time
Password
Command
Example
Result
Request condition of outputs
Password
Command
Example
Result
Store and restore relay status after power cut
Password
Command
Example
Result
V. 02 – 15/05/2012
HAMGSM133
TIN2A:xxxxxxxx
xxxxxxxx = message (max. 100 characters, all capitals)
TIN2A: TENSION ON INPUT 2
When tension is detected on input 1, an SMS is sent out with text "TENSION
ON INPUT 2". Default: ALARM! INPUT 2 HIGH
Note: a semi colon (;) is not allowed inside the message
TIN2B:xxxxxxxx
xxxxxxxx = message (max. 100 characters, all capitals)
TIN2B: NO TENSION ON INPUT 2
When no tension is detected on input 1, an SMS is sent out with text "NO
TENSION ON INPUT 2". Default: ALARM! INPUT 2 LOW
Note: a semi colon (;) is not allowed inside the message
OUTx:ON
x = 1 (output 1) or 2 (output 2)
OUT1:ON
Activate output relay 1
OUTx:OFF
x = 1 (output 1) or 2 (output 2)
OUT2:OFF
Deactivate output relay 2
OUTx:ss
x = 1 (output 1) or 2 (output 2)
ss = time in seconds (00~59)
OUT1:10
Deactivate (when already active) or activate (when deactivated) output relay
1 for the next 10 seconds.
STA?
STA?
Get an overview of the condition of the output relays.
RIPx
x = 0 (disabled) or 1 (enabled)
RIP1
Relay statuses are automatically stored when a power outage occurs and
restored when power is restored. Default: 1 (enabled)
12
©Velleman nv

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis