Operation

NOTE
The appliance vibrates during operation .
Therefore, always put it down during opera-
tion . There are four feet
the appliance for this purpose .
Remove the required accessories from the ac-
cessory compartment

Switching on and off

Switching the appliance on:
Move the ON/OFF switch
"I" to switch the appliance on . The integrated
control lamp lights up . As soon as the pressure
has built up in the appliance, the appliance
switches itself off automatically .
Switching the appliance off:
Move the ON/OFF switch
"O" to switch the appliance off . The integrated
control lamp goes out .
CAUTION!
Caution! This appliance is not designed for
continuous operation. To prevent the motor
from overheating, the appliance may only be
used as follows: within a period of 10 min-
utes the appliance may only be operated at
the rated power input for 15% of the period,
in other words, 1 .5 minutes . During the rest of
the time period (cooling phase 8 .5 minutes),
the appliance cools down again .
Compressed air hose with quick coupler
Connecting:
Push the compressed air connector
quick coupler of the compressed air hose
the sleeve automatically springs forwards .
Cutting:
Pull back the sleeve on the quick coupler of
the compressed air hose
compressed air connector
6 
GB │ IE │ NI
on the bottom of
.
into the position
into the position
into the
,
and remove the
.
CAUTION!
Caution! When disconnecting the quick
coupler of the compressed air hose
the coupler firmly to prevent injuries caused
by the hose flying off .

Inflation

with adapter
Schrader valve
Area of use:
This application allows for a simple and accurate
inflation . The manometer
tire pressure . Thanks to the integrated release valve
it is possible to reduce the tire pressure if it is
too high .
ATTENTION!
Please note, the manometer
brated! After inflation, always check the tire
pressure immediately, for example, at a petrol
station .
Ensure that the ON/OFF switch
Press the lever quick coupler
attach it .
Place the lever quick coupler
and then release the lever .
Insert the mains plug
a mains power socket .
Switch the ON/OFF switch
integrated control lamp lights up . As soon as
the pressure has built up in the appliance, the
appliance switches itself off automatically .
Pull the trigger
. The appliance switches itself
back on automatically until the pressure in the
appliance has built up .
Read the air pressure from the manometer
, hold
is used to check the
is not cali-
is set to "O" .
downwards to
onto the valve
of the compressor into
to "I" . The
.
PKZ 180 C3