Additional information

Troubleshooting

Incorrect operation is often mistaken for trouble or malfunction. If you think that there is something wrong with this component, check the points
below and the [FAQ] for the [PLX-1000] on the Pioneer DJ support site.
http://pioneerdj.com/support/
Sometimes the problem may lie in another component. Inspect the other components and electrical appliances being used. If the problem cannot
be rectified, ask your nearest Pioneer authorized service center or your dealer to carry out repair work.
This unit may not operate properly due to static electricity or other external influences. In this case, proper operation may be restored by turning the
power off, waiting 1 minute, then turning the power back on.
Problem
The power is not turned on.
No sound or small sound.
The left and right sound are reversed.
There is a low hum sound (humming
or buzzing sound) during playback.
The stylus tip does not come down on
the record.
Stylus jumping occurs.
The arm stops along the way and does
not go ahead.
Sound volume is low or loud.

Cautions on use

About condensation
Water droplets (condensation) may form inside the unit (on operating
parts and lenses) in the winter, for example, if the unit is moved from a
cold place into a warm room or if the temperature in the room in which
the unit is installed rises suddenly (through heating, etc.). The unit will
not operate properly and will not be playable with condensation inside.
Let the unit stand for 1 to 2 hours at room temperature (though this
time depends on the conditions of the condensation) without turning on
the power. The water droplets will evaporate and the unit will become
playable. Condensation can occur in the summer as well if the unit is
exposed to the direct wind from an air-conditioner, etc. If this happens,
move the unit to a different location.
When transporting the unit to another location
Use the original packing materials to pack the unit.
If the original packing materials are not available, be sure to perform the
following.
Detach the turntable sheet and turntable and pack carefully.
Detach the headshell and balance weight from the arm and pack
carefully.
Use the arm clamper to secure the tone arm and use tape to secure
it so that it does not move.
Wrap the main unit in a blanket or soft paper so that it will not be
damaged.
14
En
Check
Is the power cord properly connected?
Is the [POWER] switch for power supply set to
[ON]?
Are the audio cables properly connected?
Are the terminals and plugs dirty?
Is the headshell attached properly?
Are the left and right connections for each piece of
equipment reversed?
Is there an electric device such as a fluorescent
lamp or its power cord near the connection cord?
Is the ground wire of the turntable system
disconnected?
Is the stylus pressure adjusted property?
Is the arm horizontally balanced?
Is the stylus pressure adjusted property?
Is the record warped or does it have scratches?
Does the stylus tip have a lot of dust on it?
Is anti-skating adjusted correctly?
Is the arm height adjusted correctly?
Does the record have scratches?
Is the arm coming into contact with something?
Is the connection to the amplifier appropriate for
the cartridge type (output)?
Remedy
Properly connect the included power cord to a power outlet.
Set the [POWER] switch for power supply to [ON].
Connect the audio cables properly.
Clean the terminals and plugs before making connections.
Attach the headshell property.
Correctly connect the audio cable and the lead wires of headshell part.
Place the power cord of the fluorescent lamp or other device as far away as
possible.
Connect the ground wire properly.
Match the balance weight to the appropriate stylus pressure value for your
cartridge.
Turn the balance weight until the tone arm becomes horizontal state.
Match the balance weight to the appropriate stylus pressure value for your
cartridge.
Check the condition of the record.
Remove the shell with cartridge and use a soft tip brush or writing brush to care-
fully remove dust, etc. from the stylus tip.
Adjust anti-skating correctly.
Adjust the arm height correctly.
Check the condition of the record.
Check around the arm. If there is an obstacle, remove it.
Connect the connection cables properly.

Maintenance of each part

When attaching and detaching the headshell, turn off the power of the
amplifier.
If you attempt to do so while the volume is loud, the speaker could be
damaged.
Remove the shell with cartridge and use a soft tip brush or writing
brush to carefully remove dust, etc. from the stylus tip.
Use a good quality record cleaner to clean records.
Use a soft cloth or something similar to clean the headshell terminal
and then reattach it to the tone arm.
Cleaning the dust cover, etc.
Use a soft cloth to clean the dust cover and cabinet
Do not clean the dust cover while playing. Static electricity could
cause the tone arm to be pulled by the dust cover.
About trademarks and registered
trademarks
Pioneer is a registered trademark of PIONEER CORPORATION.
The names of companies and products mentioned herein are the trade-
marks of their respective owners.

Werbung