  • DEUTSCH, seite 1
soon as no button has been pressed for approx. 15 s
during the adjustments made in the menu.
With the button MENU (5), the following setting menu
is inserted:
(MENU)
ALARM DURATION : 02 SEC
BAUD RATE : 1200 BPS
DWELL TIME : 03 SEC
INT AUDIBLE ALARM :
EXT AUDIBLE ALARM : ON
SET TIME : 02y : 02m : 05d : 11h : 12m : 13s
DWELL SETUP (CH 01) :
ALARM POLARITY (CH 01) : HIGH
CAMERA TITLE SETUP (CH 01) : ABCDEFGHIJ
EVENT LIST
VIDEO SET
SYSTEM RESET
:SEL.ENTER : VERIFY CHOICE.MENU : EXIT
The currently selected menu item is indicated by the
arrow on the left margin.
Select a menu item with the buttons
and confirm with ENTER (8).
The individual menu items are as follows:
5.2.1 ALARM DURATION
Setting of the time for which the relay contact is closed
after occurrence of an alarm and the acoustic signal
sounds, in the range of 1 s to 99 s (as far as this was per-
mitted via the menu item 5.2.5 "EXT AUDIBLE ALARM"
or 5.2.4 "INT AUDIBLE ALARM"). The alarm can be
stopped at any time by pressing an optional button.
5.2.2 BAUD RATE – data rate for remote control
via RS-232 interface
For remote control via the serial interface, a data rate
of 1200, 2400, 3600, 4800, 9600, 19 200, 57 600, or
115 200 bits/s can be selected.
5.2.3 DWELL TIME – dwell time for automatic
sequential switching
Indication of the dwell time of each picture (1 s to 30 s)
in the automatic mode.
5.2.4 INT AUDIBLE ALARM – acoustic alarm signal
Switching ON or OFF of the acoustic signal which
sounds in case of video signal loss or alarm.
5.2.5 EXT AUDIBLE ALARM – alarm relay for
external alarm
Definition if the alarm output relay responds in case of
video signal loss or alarm via an alarm input (ON) or
not (OFF).
5.2.6 SET TIME – setting of the inserted time
Definition whether or not the current time and the date
are inserted and definition of their format. The button
ENTER (8) selects the following formats:
ON
OFF
OFF
ON
OFF
LOW
OFF
(1) and
(2)
"year/month/day/hour/minute/second"
(__y : __m : __d : __h : __m : __s),
"day/month/year/hour/minute/second"
(__d : __m : __y : __h : __m : __s)
or "TIME DISPLAY OFF". The internal clock can be set
by means of the buttons
5.2.7 DWELL SETUP – setting of the picture
sequence
Definition of the displays in the automatic mode. Select
the display (CH1, CH2, CH3, CH4, or QUAD) with the
buttons
(1) and
(2), then use the buttons
and
(4) to define if this display is to be included in
the picture sequence (ON) or not (OFF).
5.2.8 ALARM POLARITY – configuration of the
alarm inputs
Definition of the active alarm inputs and their response
either to high level or low level. Select the number of the
alarm input (CH1, CH2, CH3, or CH4) with the buttons
(1) and
(2), then use the buttons
to define if this alarm input will respond to HIGH level,
LOW level, or will not respond at all (OFF). An open
input is considered as high level. If the input is connec-
ted to ground (GND), it is set to low level.
5.2.9 CAMERA TITLE SETUP – insertion of
camera titles
For each of the four camera pictures a title of up to ten
characters can be inserted. Select the number of the
camera input (CH1, CH2, CH3, or CH4) with the but-
tons
(1) and
(2), then use the buttons + (6) and
– (7) to select a character and select the following or
previous character position with the buttons
(4). Use the button ENTER (8) to define if the title is
shown or not (UNSHOWN).
Note: Insertion of camera title, date, and time only
apply to the quad picture. In the frame display, no text
is inserted.
5.2.10 EVENT LIST – alarm protocol
The following list is inserted if this menu item is called:
CH
EVENT
YY/MM/DD
-----------------------------
CH1 VLOSS
02/01/05
CH2 ALARM
02/01/05
--- -----
--/--/--
--- -----
--/--/--
--- -----
--/--/--
--- -----
--/--/--
--- -----
--/--/--
--- -----
--/--/--
--- -----
--/--/--
--- -----
--/--/--
ENTER : CLEAR, MENU : EXIT
It shows the last ten alarm incidents and video signal
loss incidents (VLOSS), arranged according to the
time of their occurrence. Below "CH", the number of
the camera input (in case of video signal loss) or of the
alarm input (in case of alarm) is listed. Independent of
(3),
(4), + (6), and – (7).
(3) and
(3) and
HH:MM:SS
12:13:14
22:23:54
--:--:--
--:--:--
--:--:--
--:--:--
--:--:--
--:--:--
--:--:--
--:--:--
GB
(3)
(4)
15