Additional Safety Information; Residual Risks; Assembly; Installing/Changing Disc - Parkside PMNF 1350 C3 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für PMNF 1350 C3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
IE
NI

Additional safety information

a) Approved cutting disk types:
segmented diamond disks with a
maximum space of 10 mm between
segments, only with a negative cutting
angle.
Disk diameter:
Disk thickness:

RESIDUAL RISKS

Even if properly operating and handling
this electric tool, some residual risks will
remain. Due to its construction and build,
this electric tool may present the following
hazards:
a) Lung damage if suitable respiratory pro-
tection is not worn.
b) Hearing damage if suitable ear protec-
tion is not worn.
c) Damage to health due to
- touching the area of the grinding tool
which is not covered;
- ejection of parts of workpieces or
damaged grinding discs.
d) Health injuries which result from swin-
ging hand and arm, in the
the device is used over a longer period
of time or is not used and maintained
properly.
Warning! During operation, this
electric tool generates an electro-
magnetic field which, under certain
circumstances, may impair the func-
tionality of active or passive medical
implants. To reduce the risk of seri-
ous or lethal injuries, we recommend
that persons with medical implants
consult their doctor and the manu-
facturer of their medical implant
before operating the machine.
1 2
125 mm
2,1 mm
event that

Assembly

Caution! Risk of injury!
- Ensure that you have sufficient
space in which to work, and that
you do not endanger other people.
- All hoods and protective devices
must be assembled properly be-
fore commissioning.
- Disconnect the mains plug before
changing the setting on the
device.

Installing/changing disc

1. Press the spindle stop button (7).
2. Turn the mounting spindle (16)
until the spindle lock fixed the
mounting spindle. Keep and con-
tinue to hold down the spindle
lock button (7).
3. Release the clamping nut
(17) with the chuck key
(13). You can release the spindle
lock button (7.
4. Remove the threaded clamping
flange (17) through the opening
in the protective guard (15).
5. Remove the cutting disk (8) by
lifting and pulling away the take-
up spindle (16) until it reaches
the protective guard.
6. Remove the flange (21) and the
spacer disks (20) through the
opening in the protective guard
(15).
7. Remove the second cutting disk
(8) as described in point 5.
8. The take-up flange (19) can be
left on the take-up spindle (16).
If you remove the take-up flange
(19), make sure to position it cor-

Werbung