Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Care; Technical Data; Declaration Of Conformity - Conrad 84 25 46 Bedienungsanleitung

Back track gps
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operation in compass mode
• After switching the device on for the fi rst time, the device is in compass-mode
• In this operation mode, the arrow of the direction indicator (a) points north.
• The compass/distance indicator(b) shows the angle between the users' direction of move-
ment and the direction north. If the user moves f.ex. towards the east, the indicator shows
90°.
a
Operation in waypoint mode
• Press the PAGE key (1), in order to select the desired waypoint mode
• The waypoints can be stored in each of these modes. This feature is the same in all modes.
The symbols help differentiating between the different waypoints.
• Setting the waypoints can be done by saving the current coordinates or by entering known
coordinates. (see below).
• In case the required waypoints are saved, the arrow of the direction indicator (a) points in
direction of the stored waypoint (c).
• The coordinate display (b) shows the coordinates of the saved waypoint.
• The compass/distance indicator (d) shows the distance to the saved waypoint. The unit of
this indicator can be changed using the UNIT key (3).
a
By saving a waypoint, the previously stored data on this storage space is deleted.
Therefore, for saving waypoints, only use symbols that are not used yet or whose
data you don't need any more.
Saving the current coordinates
• Press the PAGE key (1), until the symbol for the desired waypoint is displayed on the display.
• If you have reached the desired waypoint (e.g. the parking space of your vehicle that you
want to mark), press the MARK key (9), until the compass/distance indicator (d) shows „0".
The waypoint has been saved.
• The direction indicator (a) is blinking to show you that you have reached the saved waypoint.
• In case you move away from the stored waypoint, the arrow of the direction indicator (a)
shows the direction and the compass/distance indicator (d) shows the distance to the stored
waypoint.
In order to save the current coordinates, a proper GPS reception will be required.
Entering known coordinates
• Press the PAGE key (1), until the symbol for the desired waypoint is displayed on the display.
• Press the UNIT key (3), until 000.000000 is shown on the coordinate display (b).
• Use the Page key (1) and the UNIT key (3) in order to select the set place and enter the
desired value using the MARK key (9).
• After having entered all values, press the UNIT key (3) for three seconds in order to save the
waypoint.
No GPS reception is required in order to enter known coordinates.
Enter the coordinates in degrees/decimal minutes. In case the data you have are
presented in any other format, you will have to convert them before entering. You will
fi nd several internet pages which will convert your data automatically.
Problem during GPS reception
.
The environmental conditions listed below can lead to a poor GPS reception and thus to incor-
rect position determinations. Try to avoid such conditions during operation.
• Operation inside tunnels or buildings (especially in reinforced concrete structures or with
• Operation in vehicles behind sun visor strips or window heaters.
• Operation near electronic devices (especially in the case of devices with radio transmitters).
• Operation near strong electric motors or transformers.
• Operation near tall buildings.
• Operation in thick forests.

Maintenance and care

b
• You do not need to service the product, apart from an occasional cleaning.
• Use only a clean, dry cloth for cleaning.
• Never use abrasive or chemical cleansers that can damage the housing.
.
Disposal
a) Product
b) Normal and Rechargeable Batteries
As the end user, you are required by law (Battery Regulation) to return used batteries and
b
rechargeable batteries. Do not dispose of used batteries in the household waste!
c
d
You can return your used batteries/rechargeable batteries free of charge at the offi cial col-
lection points of your community, in our stores, or at places where batteries or rechargeable
batteries are sold!
You thereby fulfi l your statutory obligations and contribute to the protection of the environment.

Technical data

Operating voltage ................................ V/DC
Batteries .............................................. 2 x 1.5 V micro-cell (AAA)
Operation time ..................................... approx. 27 hours
Storable waypoints .............................. 5
Cold start ............................................. < 60 seconds
Warm start ........................................... < 20 seconds
Accuracy of positioning ........................ 5 m
Operating temperature range .............. -10 °C to +60 °C
Dimensions .......................................... 53 x 88 x 26 mm
Weight ................................................. approx. 80 g

Declaration of Conformity

The manufacturer hereby declares that this product conforms to the fundamental requirements
and the other relevant regulations of Directive 1999/5/EC.
windows with metallised insulation coating.
Electronic devices are recyclable waste materials and must not be disposed of in the
household waste!
Dispose of an unserviceable product in accordance with the relevant statutory regu-
lations.
Remove any inserted battery and dispose of it separately from the product.
Batteries/rechargeable batteries contain harmful materials and are labelled with
the symbol shown to indicate that disposal in the household waste is forbidden.
The symbols of the relevant heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead
(marking can be seen on the battery/rechargeable battery, e.g. underneath the
refuse bin symbol shown on the left).
The Declaration of Conformity for this product can be found at www.conrad.com.
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2013 by Conrad Electronic SE.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis